Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.775 kW
03/20/2026 16:11 (2123 days) Production Consumption NET Usage
Now 1.198 kW 0.423 kW -0.775 kW
Today 19.078 kWh (1.178 kW) 7.396 kWh (0.457 kW) -11.682 kWh (-0.721 kW)
  - This Week 112.881 kWh (19.891 kWh/day) 112.667 kWh (19.854 kWh/day) -0.214 kWh (-0.038 kWh/day)
  - This Month 347.602 kWh (17.667 kWh/day) 316.694 kWh (16.096 kWh/day) -30.908 kWh (-1.571 kWh/day)
  - This Year 0.982 MWh (12.476 kWh/day) 1.417 MWh (18.005 kWh/day) 0.435 MWh (5.529 kWh/day)
Yesterday 13.403 kWh (0.558 kW) 14.863 kWh (0.619 kW) 1.460 kWh (0.061 kW)
Last 7 Days 150.765 kWh (21.538 kWh/day) 132.746 kWh (18.964 kWh/day) -18.019 kWh (-2.574 kWh/day)
Last 30 Days (02/18/2026) 450.900 kWh (15.030 kWh/day) 500.138 kWh (16.671 kWh/day) 49.238 kWh (1.641 kWh/day)
Last One Year 6.084 MWh (16.669 kWh/day) 7.888 MWh (21.610 kWh/day) 1.803 MWh (4.941 kWh/day)
Lifetime Since PTO 36.547 MWh (17.209 kW/day) 40.927 MWh (19.272 kW/day) 4.380 MWh (2.063 kW/day)
Lifetime Since Install 36.581 MWh 41.507 MWh 4.926 MWh
Voltage/Current 250.6 V / 4.8 A 250.4 V / 1.7 A 250.5 V / -3.1 A
Meter

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 09/23/2025 23:51 (23.7 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 22.262 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.243 1.192 1.040 9.726 0.000 kW
1.160 kWh
0.000 kW
6.963 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.229 1.138 0.990 9.307
03 - 202224****** IQ7+M [5] VCOP 0.000 0.237 1.181 1.029 9.653
04 - 202232****** IQ7+ [5] VCOP 0.000 0.240 1.183 1.039 9.727
05 - 202244****** IQ7+M [5] VCOP 0.000 0.230 1.118 0.982 9.056
06 - 202245****** IQ7+M [5] VCOP 0.000 0.235 1.151 1.013 9.283
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.250 1.179 1.048 9.306 0.000 kW
1.209 kWh
0.000 kW
6.044 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.259 1.204 1.061 9.972
09 - 202217****** IQ7+ [5] VCOP 0.000 0.255 1.218 1.064 9.958
10 - 202244****** IQ7+M [5] VCOP 0.000 0.247 1.218 1.068 9.972
11 - 202224****** IQ7+M [5] VCOP 0.000 0.258 1.226 1.078 10.106
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.183 0.903 0.794 7.530 0.000 kW
0.939 kWh
0.000 kW
3.757 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.187 0.937 0.826 7.703
14 - 202216****** IQ7+ [5] VCOP 0.000 0.188 0.957 0.857 7.978
15 - 202245****** IQ7+M [5] VCOP 0.000 0.188 0.960 0.863 7.989
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.749 kWh
0.230 kW
5.498 kWh
17 - 122214****** IQ7PD [5] VCOP 0.230 0.230 5.498 5.502 38.543
Panel Layout Each Group Production

Charger History
Voltage PV 0.79 V Voltage Charge 52.16 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.6 °C / 27.8 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-09-23 23:55
voltage in/out power and energy

Battery History
Voltage 52.44 V Current/Power -6.32 A (-0.331 kW)
Remain Capacity/Energy 173.7 Ah (8.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 29.3 % State Of Health 98.9 %
Run Time 1d 3h 29m to empty Report Date 2025-09-23 23:55
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.