Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.460 kW
11/02/2025 13:21 (1985 days) Production Consumption NET Usage
Now 2.844 kW 0.384 kW -2.460 kW
Today 13.015 kWh (0.974 kW) 6.089 kWh (0.455 kW) -6.926 kWh (-0.518 kW)
  - This Week 13.015 kWh (23.365 kWh/day) 6.089 kWh (10.931 kWh/day) -6.926 kWh (-12.434 kWh/day)
  - This Month 29.953 kWh (19.233 kWh/day) 22.277 kWh (14.304 kWh/day) -7.676 kWh (-4.929 kWh/day)
  - This Year 5.608 MWh (18.353 kWh/day) 6.355 MWh (20.797 kWh/day) 0.747 MWh (2.444 kWh/day)
Yesterday 16.938 kWh (0.705 kW) 16.188 kWh (0.674 kW) -0.750 kWh (-0.031 kW)
Last 7 Days 84.554 kWh (12.079 kWh/day) 68.911 kWh (9.845 kWh/day) -15.643 kWh (-2.235 kWh/day)
Last 30 Days 448.063 kWh (14.935 kWh/day) 470.286 kWh (15.676 kWh/day) 22.223 kWh (0.741 kWh/day)
Last One Year 6.208 MWh (17.009 kWh/day) 7.413 MWh (20.310 kWh/day) 1.205 MWh (3.301 kWh/day)
Lifetime Since PTO 35.059 MWh (17.657 kW/day) 38.307 MWh (19.293 kW/day) 3.249 MWh (1.636 kW/day)
Lifetime Since Install 35.093 MWh 38.887 MWh 3.795 MWh
Voltage/Current 249.6 V / 11.4 A 249.8 V / 1.5 A 249.7 V / -9.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/17/2020 20:39 (5.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 0.282 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.000 0.000 0.190 3.475 0.000 kW
0.001 kWh
0.000 kW
0.004 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.179 3.356
03 - 202224****** IQ7+M [5] VCOP 0.000 0.002 0.001 0.189 3.314
04 - 202232****** IQ7+ [5] VCOP 0.000 0.002 0.001 0.186 3.156
05 - 202244****** IQ7+M [5] VCOP 0.000 0.002 0.001 0.174 3.561
06 - 202245****** IQ7+M [5] VCOP 0.000 0.002 0.001 0.180 3.632
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.005 0.002 0.168 4.225 0.000 kW
0.005 kWh
0.000 kW
0.023 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.004 0.001 0.042 0.042
09 - 202217****** IQ7+ [5] VCOP 0.000 0.005 0.007 0.170 4.528
10 - 202244****** IQ7+M [5] VCOP 0.000 0.006 0.008 0.173 4.481
11 - 202224****** IQ7+M [5] VCOP 0.000 0.005 0.005 0.168 4.148
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.016 0.050 0.191 1.778 0.000 kW
0.064 kWh
0.000 kW
0.255 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.013 0.040 0.192 1.950
14 - 202216****** IQ7+ [5] VCOP 0.000 0.012 0.036 0.196 1.952
15 - 202245****** IQ7+M [5] VCOP 0.000 0.050 0.130 0.192 1.896
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.49 V Current/Power 163.90 A (8.602 kW)
Remain Capacity/Energy 363.9 Ah (18.6 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 61.6 % State Of Health 98.5 %
Run Time 1h 23m to full Report Date 2020-12-17 23:26
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.49 V Cell (MIN/MAX) 3.275 V / 3.285 V (0.010 V)
Current/Power -0.50 A (-26 W) Runtime 10d 1h 10m to empty
Remain Capacity/Energy 121.3 Ah (6.2 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 61.6 % State Of Health 98.5 %
Temperature 22.0 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-17 23:26
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.275 V 3.275 V 3.276 V 3.277 V 3.278 V 3.278 V 3.279 V 3.279 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.281 V 3.281 V 3.282 V 3.282 V 3.283 V 3.283 V 3.284 V 3.285 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -