Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.748 kW
07/10/2025 03:28 (1870 days) Production Consumption NET Usage
Now 0.000 kW 0.748 kW 0.748 kW
Today 0.000 kWh (0.000 kW) 3.339 kWh (0.951 kW) 3.339 kWh (0.951 kW)
  - This Week 99.595 kWh (24.021 kWh/day) 195.416 kWh (47.131 kWh/day) 95.821 kWh (23.111 kWh/day)
  - This Month 229.304 kWh (25.072 kWh/day) 364.142 kWh (39.815 kWh/day) 134.838 kWh (14.743 kWh/day)
  - This Year 3.259 MWh (17.140 kWh/day) 3.491 MWh (18.362 kWh/day) 0.232 MWh (1.222 kWh/day)
Yesterday 25.046 kWh (1.044 kW) 40.411 kWh (1.684 kW) 15.365 kWh (0.640 kW)
Last 7 Days 187.533 kWh (26.791 kWh/day) 299.677 kWh (42.813 kWh/day) 112.144 kWh (16.021 kWh/day)
Last 30 Days 652.855 kWh (21.763 kWh/day) 970.553 kWh (32.353 kWh/day) 317.698 kWh (10.590 kWh/day)
Last One Year 6.296 MWh (17.249 kWh/day) 6.482 MWh (17.760 kWh/day) 0.186 MWh (0.511 kWh/day)
Lifetime Since PTO 32.710 MWh (17.491 kW/day) 35.443 MWh (18.952 kW/day) 2.733 MWh (1.462 kW/day)
Lifetime Since Install 32.744 MWh 36.023 MWh 3.280 MWh
Voltage/Current 252.1 V / 0.0 A 252.0 V / 3.0 A 252.1 V / 3.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/23/2020 23:45 (13.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.892 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.877 1.602 10.615 0.000 kW
1.862 kWh
0.000 kW
11.171 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.294 1.854 1.580 10.405
03 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.887 1.603 10.610
04 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.896 1.600 10.654
05 - 202244****** IQ7+M [0] ---- 0.000 0.295 1.814 1.542 9.948
06 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.844 1.573 10.253
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 1.882 1.531 10.050 0.000 kW
1.894 kWh
0.000 kW
9.470 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.295 1.888 1.583 10.185
09 - 202217****** IQ7+ [0] ---- 0.000 0.295 1.881 1.529 10.036
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.908 1.592 10.338
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.911 1.604 10.376
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.266 1.578 1.342 9.653 0.000 kW
1.563 kWh
0.000 kW
6.250 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.268 1.507 1.312 9.279
14 - 202216****** IQ7+ [0] ---- 0.000 0.269 1.592 1.347 9.667
15 - 202245****** IQ7+M [0] ---- 0.000 0.265 1.572 1.325 9.504
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 52.10 V Current/Power 162.65 A (8.474 kW)
Remain Capacity/Energy 176.7 Ah (9.0 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 30.6 % State Of Health 96.2 %
Run Time 2h 27m to full Report Date 2020-08-23 23:40
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.10 V Cell (MIN/MAX) 3.249 V / 3.262 V (0.013 V)
Current/Power -0.53 A (-27 W) Runtime 4d 15h 20m to empty
Remain Capacity/Energy 58.9 Ah (3.0 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 30.6 % State Of Health 96.2 %
Temperature 26.0 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-23 23:40
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.249 V 3.250 V 3.251 V 3.251 V 3.256 V 3.253 V 3.256 V 3.256 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.256 V 3.255 V 3.258 V 3.257 V 3.259 V 3.260 V 3.262 V 3.262 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -