Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 3.426 kW
07/09/2025 19:03 (1869 days) Production Consumption NET Usage
Now 0.161 kW 3.587 kW 3.426 kW
Today 24.972 kWh (1.308 kW) 28.921 kWh (1.515 kW) 3.949 kWh (0.207 kW)
  - This Week 99.521 kWh (26.220 kWh/day) 180.587 kWh (47.578 kWh/day) 81.066 kWh (21.358 kWh/day)
  - This Month 229.230 kWh (26.063 kWh/day) 349.313 kWh (39.716 kWh/day) 120.083 kWh (13.653 kWh/day)
  - This Year 3.259 MWh (17.171 kWh/day) 3.477 MWh (18.317 kWh/day) 0.218 MWh (1.147 kWh/day)
Yesterday 25.246 kWh (1.052 kW) 40.320 kWh (1.681 kW) 15.074 kWh (0.628 kW)
Last 7 Days 183.276 kWh (26.183 kWh/day) 289.029 kWh (41.290 kWh/day) 105.753 kWh (15.108 kWh/day)
Last 30 Days 633.297 kWh (21.111 kWh/day) 941.634 kWh (31.389 kWh/day) 308.337 kWh (10.278 kWh/day)
Last One Year 6.301 MWh (17.264 kWh/day) 6.479 MWh (17.750 kWh/day) 0.177 MWh (0.486 kWh/day)
Lifetime Since PTO 32.710 MWh (17.494 kW/day) 35.429 MWh (18.948 kW/day) 2.719 MWh (1.454 kW/day)
Lifetime Since Install 32.744 MWh 36.008 MWh 3.265 MWh
Voltage/Current 248.5 V / 0.6 A 248.5 V / 14.4 A 248.5 V / 13.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/14/2020 22:37 (13.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 20.242 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.409 0.701 10.246 0.000 kW
1.372 kWh
0.000 kW
8.229 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.372 0.693 10.023
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.401 0.706 10.215
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.414 0.696 10.226
05 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.277 0.678 9.475
06 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.356 0.690 9.962
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.293 1.240 0.614 9.398 0.000 kW
1.244 kWh
0.000 kW
6.219 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.226 0.627 9.557
09 - 202217****** IQ7+ [5] VCOP 0.000 0.292 1.239 0.620 9.462
10 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.254 0.631 9.699
11 - 202224****** IQ7+M [5] VCOP 0.000 0.293 1.260 0.634 9.709
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.279 1.446 0.702 9.677 0.000 kW
1.448 kWh
0.000 kW
5.794 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.279 1.444 0.705 9.443
14 - 202216****** IQ7+ [5] VCOP 0.000 0.281 1.459 0.716 9.741
15 - 202245****** IQ7+M [5] VCOP 0.000 0.278 1.445 0.709 9.599
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 53.20 V Current/Power 166.16 A (8.840 kW)
Remain Capacity/Energy 512.4 Ah (26.2 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 88.8 % State Of Health 96.2 %
Run Time 23m to full Report Date 2020-08-14 23:57
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.20 V Cell (MIN/MAX) 3.319 V / 3.329 V (0.010 V)
Current/Power -0.52 A (-27 W) Runtime 13d 19h 39m to empty
Remain Capacity/Energy 170.8 Ah (8.7 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 88.8 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-14 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.319 V 3.321 V 3.321 V 3.322 V 3.322 V 3.323 V 3.324 V 3.324 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.326 V 3.326 V 3.327 V 3.327 V 3.329 V 3.328 V 3.329 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -