Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.342 kW
05/21/2026 00:48 (2185 days) Production Consumption NET Usage
Now 0.000 kW 0.342 kW 0.342 kW
Today 0.000 kWh (0.000 kW) 0.624 kWh (0.749 kW) 0.624 kWh (0.749 kW)
  - This Week 116.795 kWh (28.950 kWh/day) 130.308 kWh (32.299 kWh/day) 13.513 kWh (3.349 kWh/day)
  - This Month 518.611 kWh (25.887 kWh/day) 330.030 kWh (16.474 kWh/day) -188.581 kWh (-9.413 kWh/day)
  - This Year 2.472 MWh (17.650 kWh/day) 2.390 MWh (17.065 kWh/day) -0.082 MWh (-0.585 kWh/day)
Yesterday 25.684 kWh (1.070 kW) 42.704 kWh (1.779 kW) 17.020 kWh (0.709 kW)
Last 7 Days 192.964 kWh (27.566 kWh/day) 161.170 kWh (23.024 kWh/day) -31.794 kWh (-4.542 kWh/day)
Last 30 Days (04/21/2026) 722.358 kWh (24.079 kWh/day) 412.480 kWh (13.749 kWh/day) -309.878 kWh (-10.329 kWh/day)
Last One Year 6.363 MWh (17.433 kWh/day) 7.796 MWh (21.358 kWh/day) 1.433 MWh (3.925 kWh/day)
Lifetime Since PTO 38.037 MWh (17.408 kW/day) 41.901 MWh (19.176 kW/day) 3.863 MWh (1.768 kW/day)
Lifetime Since Install 38.071 MWh 42.480 MWh 4.409 MWh
Voltage/Current 249.8 V / 0.0 A 249.7 V / 1.4 A 249.7 V / 1.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/25/2021 20:34 (14.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.350 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.292 2.213 2.291 12.439 0.000 kW
2.175 kWh
0.000 kW
13.050 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.285 2.160 2.191 11.896
03 - 202224****** IQ7+M [0] ---- 0.000 0.295 2.214 2.193 11.939
04 - 202232****** IQ7+ [0] ---- 0.000 0.293 2.219 2.225 12.055
05 - 202244****** IQ7+M [0] ---- 0.000 0.289 2.083 1.986 10.854
06 - 202245****** IQ7+M [0] ---- 0.000 0.285 2.161 2.233 12.052
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.292 2.039 1.971 10.811 0.000 kW
2.068 kWh
0.000 kW
10.338 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.295 2.064 2.071 11.072
09 - 202217****** IQ7+ [0] ---- 0.000 0.294 2.068 2.027 10.990
10 - 202244****** IQ7+M [0] ---- 0.000 0.294 2.080 2.092 11.223
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 2.087 2.116 11.246
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.269 2.005 2.347 12.802 0.000 kW
1.990 kWh
0.000 kW
7.962 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.266 1.945 2.241 12.454
14 - 202216****** IQ7+ [0] ---- 0.000 0.267 2.020 2.360 12.834
15 - 202245****** IQ7+M [0] ---- 0.000 0.262 1.992 2.323 12.635
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 531.9 Ah (27.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 88.7 % State Of Health 100.0 %
Run Time 24d 15h 0m to empty Report Date 2021-06-25 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.