Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 4.721 kW
08/26/2025 18:49 (1917 days) Production Consumption NET Usage
Now 0.258 kW 4.979 kW 4.721 kW
Today 24.343 kWh (1.293 kW) 9.905 kWh (0.526 kW) -14.438 kWh (-0.767 kW)
  - This Week 71.171 kWh (25.560 kWh/day) 55.216 kWh (19.830 kWh/day) -15.955 kWh (-5.730 kWh/day)
  - This Month 624.274 kWh (24.211 kWh/day) 739.798 kWh (28.691 kWh/day) 115.524 kWh (4.480 kWh/day)
  - This Year 4.382 MWh (18.428 kWh/day) 5.077 MWh (21.353 kWh/day) 0.695 MWh (2.924 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.833 MWh (17.642 kW/day) 37.029 MWh (19.308 kW/day) 3.196 MWh (1.667 kW/day)
Lifetime Since Install 33.867 MWh 37.609 MWh 3.743 MWh
Voltage/Current 247.4 V / 1.0 A 247.2 V / 20.1 A 247.3 V / 19.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/21/2020 23:04 (12.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.969 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.268 1.826 1.818 10.889 0.000 kW
1.808 kWh
0.000 kW
10.850 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.265 1.813 1.809 10.790
03 - 202224****** IQ7+M [5] VCOP 0.000 0.269 1.842 1.837 10.958
04 - 202232****** IQ7+ [5] VCOP 0.000 0.268 1.832 1.832 10.888
05 - 202244****** IQ7+M [5] VCOP 0.000 0.267 1.776 1.758 10.609
06 - 202245****** IQ7+M [5] VCOP 0.000 0.263 1.762 1.742 10.595
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.921 1.888 11.146 0.000 kW
1.905 kWh
0.000 kW
9.527 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.799 1.797 10.711
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.927 1.893 11.205
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.945 1.918 11.314
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.934 1.911 11.241
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.203 1.408 1.412 8.841 0.000 kW
1.398 kWh
0.000 kW
5.592 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.204 1.376 1.370 8.693
14 - 202216****** IQ7+ [5] VCOP 0.000 0.205 1.416 1.422 8.894
15 - 202245****** IQ7+M [5] VCOP 0.000 0.201 1.392 1.399 8.755
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.62 V Current/Power 179.79 A (10.359 kW)
Remain Capacity/Energy 574.8 Ah (29.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 97.3 % State Of Health 98.5 %
Run Time 5m to full Report Date 2020-09-21 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.62 V Cell (MIN/MAX) 3.586 V / 3.606 V (0.020 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 191.6 Ah (9.8 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 97.3 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-21 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.598 V 3.586 V 3.602 V 3.598 V 3.600 V 3.589 V 3.605 V 3.604 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.600 V 3.602 V 3.605 V 3.603 V 3.603 V 3.603 V 3.606 V 3.606 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -