Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.812 kW
05/24/2025 12:25 (1823 days) Production Consumption NET Usage
Now 2.221 kW 0.409 kW -1.812 kW
Today 7.975 kWh (0.641 kW) 6.070 kWh (0.488 kW) -1.905 kWh (-0.153 kW)
  - This Week 116.445 kWh (17.863 kWh/day) 141.050 kWh (21.637 kWh/day) 24.605 kWh (3.774 kWh/day)
  - This Month 433.080 kWh (18.415 kWh/day) 390.200 kWh (16.592 kWh/day) -42.880 kWh (-1.823 kWh/day)
  - This Year 2.256 MWh (15.722 kWh/day) 2.199 MWh (15.322 kWh/day) -0.057 MWh (-0.400 kWh/day)
Yesterday 15.106 kWh (0.630 kW) 14.115 kWh (0.589 kW) -0.991 kWh (-0.041 kW)
Last 7 Days 134.846 kWh (19.264 kWh/day) 157.675 kWh (22.525 kWh/day) 22.829 kWh (3.261 kWh/day)
Last 30 Days 604.047 kWh (20.136 kWh/day) 519.793 kWh (17.327 kWh/day) -84.254 kWh (-2.809 kWh/day)
Last One Year 6.642 MWh (18.196 kWh/day) 6.289 MWh (17.230 kWh/day) -0.353 MWh (-0.966 kWh/day)
Lifetime Since PTO 31.707 MWh (17.388 kW/day) 34.151 MWh (18.728 kW/day) 2.444 MWh (1.340 kW/day)
Lifetime Since Install 31.741 MWh 34.731 MWh 2.990 MWh
Voltage/Current 250.5 V / 8.9 A 250.5 V / 1.6 A 250.5 V / -7.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/17/2020 22:17 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.241 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.087 2.338 14.397 0.000 kW
1.999 kWh
0.000 kW
11.995 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 2.015 2.261 13.912
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 2.006 2.238 13.845
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.028 2.269 13.979
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.813 2.049 12.687
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.045 2.295 14.113
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.843 2.018 12.550 0.000 kW
1.840 kWh
0.000 kW
9.202 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.841 2.134 12.974
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.839 2.065 12.706
10 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.843 2.141 13.039
11 - 202224****** IQ7+M [5] VCOP 0.000 0.293 1.836 2.153 13.063
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.278 2.268 2.357 14.687 0.000 kW
2.261 kWh
0.000 kW
9.044 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.278 2.261 2.269 14.270
14 - 202216****** IQ7+ [5] VCOP 0.000 0.278 2.279 2.362 14.709
15 - 202245****** IQ7+M [5] VCOP 0.000 0.273 2.236 2.323 14.446
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 220

Battery History
Voltage 53.37 V Current/Power 166.64 A (8.893 kW)
Remain Capacity/Energy 575.7 Ah (29.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.7 % State Of Health 96.2 %
Run Time - to full Report Date 2020-06-17 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.37 V Cell (MIN/MAX) 3.329 V / 3.340 V (0.011 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 191.9 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.7 % State Of Health 96.2 %
Temperature 23.5 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-17 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.330 V 3.329 V 3.333 V 3.330 V 3.335 V 3.334 V 3.333 V 3.336 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.337 V 3.335 V 3.337 V 3.335 V 3.338 V 3.337 V 3.340 V 3.340 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -