Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.110 kW
11/02/2025 14:41 (1985 days) Production Consumption NET Usage
Now 1.343 kW 0.233 kW -1.110 kW
Today 16.183 kWh (1.102 kW) 6.398 kWh (0.435 kW) -9.785 kWh (-0.666 kW)
  - This Week 16.183 kWh (26.437 kWh/day) 6.398 kWh (10.452 kWh/day) -9.785 kWh (-15.985 kWh/day)
  - This Month 33.121 kWh (20.540 kWh/day) 22.586 kWh (14.007 kWh/day) -10.535 kWh (-6.533 kWh/day)
  - This Year 5.611 MWh (18.360 kWh/day) 6.355 MWh (20.794 kWh/day) 0.744 MWh (2.434 kWh/day)
Yesterday 16.938 kWh (0.705 kW) 16.188 kWh (0.674 kW) -0.750 kWh (-0.031 kW)
Last 7 Days 84.554 kWh (12.079 kWh/day) 68.911 kWh (9.845 kWh/day) -15.643 kWh (-2.235 kWh/day)
Last 30 Days 448.063 kWh (14.935 kWh/day) 470.286 kWh (15.676 kWh/day) 22.223 kWh (0.741 kWh/day)
Last One Year 6.208 MWh (17.009 kWh/day) 7.413 MWh (20.310 kWh/day) 1.205 MWh (3.301 kWh/day)
Lifetime Since PTO 35.062 MWh (17.658 kW/day) 38.308 MWh (19.292 kW/day) 3.246 MWh (1.635 kW/day)
Lifetime Since Install 35.096 MWh 38.888 MWh 3.792 MWh
Voltage/Current 249.4 V / 5.4 A 249.4 V / 0.9 A 249.4 V / -4.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/19/2020 20:46 (9.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.107 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.247 0.935 1.013 4.379 0.000 kW
0.919 kWh
0.000 kW
5.511 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.247 0.918 1.003 4.389
03 - 202224****** IQ7+M [5] VCOP 0.000 0.248 0.920 1.010 4.413
04 - 202232****** IQ7+ [5] VCOP 0.000 0.248 0.884 0.984 4.278
05 - 202244****** IQ7+M [5] VCOP 0.000 0.250 0.928 1.021 4.310
06 - 202245****** IQ7+M [5] VCOP 0.000 0.247 0.926 1.000 4.150
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.076 1.184 4.967 0.000 kW
1.098 kWh
0.000 kW
5.489 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.012 1.129 4.523
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.153 1.307 5.434
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.148 1.283 5.375
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.100 1.204 5.085
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.125 0.504 0.451 2.475 0.000 kW
0.527 kWh
0.000 kW
2.107 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.128 0.540 0.518 2.695
14 - 202216****** IQ7+ [5] VCOP 0.000 0.128 0.538 0.511 2.613
15 - 202245****** IQ7+M [5] VCOP 0.000 0.125 0.525 0.496 2.603
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.45 V Current/Power 163.79 A (8.590 kW)
Remain Capacity/Energy 324.9 Ah (16.6 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 55.0 % State Of Health 98.5 %
Run Time 1h 37m to full Report Date 2020-11-18 16:58
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.45 V Cell (MIN/MAX) 3.272 V / 3.282 V (0.010 V)
Current/Power -0.50 A (-26 W) Runtime 9d 0h 36m to empty
Remain Capacity/Energy 108.3 Ah (5.5 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 55.0 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-18 16:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.272 V 3.273 V 3.274 V 3.275 V 3.276 V 3.276 V 3.277 V 3.277 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.278 V 3.278 V 3.279 V 3.279 V 3.281 V 3.281 V 3.281 V 3.282 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -