Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 4.667 kW
11/02/2025 19:47 (1985 days) Production Consumption NET Usage
Now 0.000 kW 4.667 kW 4.667 kW
Today 17.171 kWh (0.867 kW) 20.597 kWh (1.040 kW) 3.426 kWh (0.173 kW)
  - This Week 17.171 kWh (20.817 kWh/day) 20.597 kWh (24.971 kWh/day) 3.426 kWh (4.153 kWh/day)
  - This Month 34.109 kWh (18.688 kWh/day) 36.785 kWh (20.154 kWh/day) 2.676 kWh (1.466 kWh/day)
  - This Year 5.612 MWh (18.351 kWh/day) 6.369 MWh (20.826 kWh/day) 0.757 MWh (2.476 kWh/day)
Yesterday 16.938 kWh (0.705 kW) 16.188 kWh (0.674 kW) -0.750 kWh (-0.031 kW)
Last 7 Days 84.554 kWh (12.079 kWh/day) 68.911 kWh (9.845 kWh/day) -15.643 kWh (-2.235 kWh/day)
Last 30 Days 448.063 kWh (14.935 kWh/day) 470.286 kWh (15.676 kWh/day) 22.223 kWh (0.741 kWh/day)
Last One Year 6.208 MWh (17.009 kWh/day) 7.413 MWh (20.310 kWh/day) 1.205 MWh (3.301 kWh/day)
Lifetime Since PTO 35.063 MWh (17.656 kW/day) 38.322 MWh (19.297 kW/day) 3.259 MWh (1.641 kW/day)
Lifetime Since Install 35.097 MWh 38.902 MWh 3.805 MWh
Voltage/Current 245.9 V / 0.0 A 245.8 V / 19.0 A 245.9 V / 19.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/17/2020 20:53 (9.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.735 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.147 0.397 1.152 4.074 0.000 kW
0.392 kWh
0.000 kW
2.350 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.146 0.392 1.133 4.086
03 - 202224****** IQ7+M [0] ---- 0.000 0.151 0.399 1.126 4.107
04 - 202232****** IQ7+ [0] ---- 0.000 0.145 0.388 1.082 3.983
05 - 202244****** IQ7+M [0] ---- 0.000 0.147 0.387 1.165 4.008
06 - 202245****** IQ7+M [0] ---- 0.000 0.146 0.389 1.136 3.860
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.168 0.388 1.351 4.587 0.000 kW
0.391 kWh
0.000 kW
1.957 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.168 0.385 1.196 4.055
09 - 202217****** IQ7+ [0] ---- 0.000 0.172 0.396 1.495 5.013
10 - 202244****** IQ7+M [0] ---- 0.000 0.169 0.398 1.475 4.970
11 - 202224****** IQ7+M [0] ---- 0.000 0.168 0.390 1.379 4.694
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.093 0.355 0.501 2.356 0.000 kW
0.357 kWh
0.000 kW
1.429 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.095 0.357 0.572 2.535
14 - 202216****** IQ7+ [0] ---- 0.000 0.095 0.363 0.564 2.459
15 - 202245****** IQ7+M [0] ---- 0.000 0.093 0.354 0.548 2.455
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.47 V Current/Power 163.88 A (8.599 kW)
Remain Capacity/Energy 351.3 Ah (18.0 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 59.4 % State Of Health 98.5 %
Run Time 1h 27m to full Report Date 2020-11-17 23:54
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.47 V Cell (MIN/MAX) 3.274 V / 3.284 V (0.010 V)
Current/Power -0.51 A (-26 W) Runtime 9d 15h 26m to empty
Remain Capacity/Energy 117.1 Ah (6.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 59.4 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-17 23:54
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.274 V 3.275 V 3.276 V 3.276 V 3.277 V 3.278 V 3.278 V 3.279 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.280 V 3.280 V 3.281 V 3.281 V 3.282 V 3.283 V 3.283 V 3.284 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -