Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.638 kW
11/02/2025 14:53 (1985 days) Production Consumption NET Usage
Now 1.020 kW 0.382 kW -0.638 kW
Today 16.419 kWh (1.102 kW) 6.457 kWh (0.433 kW) -9.962 kWh (-0.669 kW)
  - This Week 16.419 kWh (26.451 kWh/day) 6.457 kWh (10.402 kWh/day) -9.962 kWh (-16.049 kWh/day)
  - This Month 33.357 kWh (20.577 kWh/day) 22.645 kWh (13.969 kWh/day) -10.712 kWh (-6.608 kWh/day)
  - This Year 5.611 MWh (18.360 kWh/day) 6.355 MWh (20.794 kWh/day) 0.744 MWh (2.434 kWh/day)
Yesterday 16.938 kWh (0.705 kW) 16.188 kWh (0.674 kW) -0.750 kWh (-0.031 kW)
Last 7 Days 84.554 kWh (12.079 kWh/day) 68.911 kWh (9.845 kWh/day) -15.643 kWh (-2.235 kWh/day)
Last 30 Days 448.063 kWh (14.935 kWh/day) 470.286 kWh (15.676 kWh/day) 22.223 kWh (0.741 kWh/day)
Last One Year 6.208 MWh (17.009 kWh/day) 7.413 MWh (20.310 kWh/day) 1.205 MWh (3.301 kWh/day)
Lifetime Since PTO 35.062 MWh (17.658 kW/day) 38.308 MWh (19.292 kW/day) 3.246 MWh (1.635 kW/day)
Lifetime Since Install 35.096 MWh 38.888 MWh 3.792 MWh
Voltage/Current 248.9 V / 4.1 A 248.8 V / 1.5 A 248.9 V / -2.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/15/2020 20:21 (8.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.925 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.181 0.422 1.117 4.666 0.000 kW
0.414 kWh
0.000 kW
2.483 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.178 0.414 1.131 4.685
03 - 202224****** IQ7+M [5] VCOP 0.000 0.172 0.415 1.136 4.748
04 - 202232****** IQ7+ [5] VCOP 0.000 0.166 0.403 1.100 4.648
05 - 202244****** IQ7+M [5] VCOP 0.000 0.183 0.412 1.061 4.620
06 - 202245****** IQ7+M [5] VCOP 0.000 0.180 0.417 0.931 4.483
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.201 0.412 1.321 5.336 0.000 kW
0.397 kWh
0.000 kW
1.985 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.199 0.318 1.179 4.772
09 - 202217****** IQ7+ [5] VCOP 0.000 0.201 0.422 1.472 5.943
10 - 202244****** IQ7+M [5] VCOP 0.000 0.203 0.422 1.462 5.864
11 - 202224****** IQ7+M [5] VCOP 0.000 0.200 0.412 1.375 5.500
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.123 0.363 0.520 2.600 0.000 kW
0.364 kWh
0.000 kW
1.457 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.126 0.365 0.590 2.821
14 - 202216****** IQ7+ [5] VCOP 0.000 0.126 0.368 0.544 2.746
15 - 202245****** IQ7+M [5] VCOP 0.000 0.124 0.361 0.564 2.734
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.09 V Current/Power 165.74 A (8.799 kW)
Remain Capacity/Energy 426.0 Ah (21.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 72.1 % State Of Health 98.5 %
Run Time 59m to full Report Date 2020-11-15 23:40
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.09 V Cell (MIN/MAX) 3.312 V / 3.323 V (0.011 V)
Current/Power -0.51 A (-27 W) Runtime 11d 13h 53m to empty
Remain Capacity/Energy 142.0 Ah (7.3 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 72.1 % State Of Health 98.5 %
Temperature 25.0 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-15 23:40
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.312 V 3.313 V 3.314 V 3.313 V 3.316 V 3.313 V 3.316 V 3.317 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.320 V 3.318 V 3.320 V 3.320 V 3.322 V 3.323 V 3.323 V 3.323 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -