Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.583 kW
07/10/2025 11:25 (1870 days) Production Consumption NET Usage
Now 1.397 kW 0.814 kW -0.583 kW
Today 3.037 kWh (0.265 kW) 9.621 kWh (0.839 kW) 6.584 kWh (0.574 kW)
  - This Week 102.632 kWh (22.921 kWh/day) 201.698 kWh (45.046 kWh/day) 99.066 kWh (22.125 kWh/day)
  - This Month 232.341 kWh (24.516 kWh/day) 370.424 kWh (39.086 kWh/day) 138.083 kWh (14.570 kWh/day)
  - This Year 3.262 MWh (17.126 kWh/day) 3.498 MWh (18.363 kWh/day) 0.236 MWh (1.237 kWh/day)
Yesterday 25.046 kWh (1.044 kW) 40.411 kWh (1.684 kW) 15.365 kWh (0.640 kW)
Last 7 Days 187.533 kWh (26.791 kWh/day) 299.677 kWh (42.813 kWh/day) 112.144 kWh (16.021 kWh/day)
Last 30 Days 652.855 kWh (21.763 kWh/day) 970.553 kWh (32.353 kWh/day) 317.698 kWh (10.590 kWh/day)
Last One Year 6.296 MWh (17.249 kWh/day) 6.482 MWh (17.760 kWh/day) 0.186 MWh (0.511 kWh/day)
Lifetime Since PTO 32.713 MWh (17.489 kW/day) 35.450 MWh (18.952 kW/day) 2.737 MWh (1.463 kW/day)
Lifetime Since Install 32.747 MWh 36.030 MWh 3.283 MWh
Voltage/Current 248.5 V / 5.6 A 248.5 V / 3.3 A 248.5 V / -2.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/14/2020 22:51 (14.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 32.250 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.265 2.225 10.444 0.000 kW
2.172 kWh
0.000 kW
13.030 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.299 2.184 2.150 10.156
03 - 202224****** IQ7+M [5] VCOP 0.000 0.298 2.177 2.154 10.216
04 - 202232****** IQ7+ [5] VCOP 0.000 0.298 2.197 2.159 10.227
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.996 1.992 9.562
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.210 2.171 10.227
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.968 1.947 9.197 0.000 kW
2.041 kWh
0.000 kW
10.203 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.067 2.042 9.524
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 2.009 1.985 9.376
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 2.079 2.053 9.633
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.081 2.063 9.617
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.289 2.299 2.179 10.398 0.000 kW
2.254 kWh
0.000 kW
9.017 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.288 2.205 2.082 10.124
14 - 202216****** IQ7+ [5] VCOP 0.000 0.289 2.278 2.162 10.427
15 - 202245****** IQ7+M [5] VCOP 0.000 0.282 2.234 2.121 10.272
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 53.08 V Current/Power 165.68 A (8.795 kW)
Remain Capacity/Energy 406.8 Ah (20.8 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 70.5 % State Of Health 96.2 %
Run Time 1h 1m to full Report Date 2020-07-14 23:12
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.08 V Cell (MIN/MAX) 3.311 V / 3.323 V (0.012 V)
Current/Power -0.53 A (-28 W) Runtime 10d 13h 55m to empty
Remain Capacity/Energy 135.6 Ah (6.9 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 70.5 % State Of Health 96.2 %
Temperature 25.1 °C Cycle 23
MOSFET CFET = ON, DFET = ON Reported 2020-07-14 23:12
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.313 V 3.312 V 3.313 V 3.312 V 3.316 V 3.311 V 3.316 V 3.315 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.319 V 3.318 V 3.320 V 3.320 V 3.322 V 3.323 V 3.323 V 3.323 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -