Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 6.138 kW
11/02/2025 18:38 (1985 days) Production Consumption NET Usage
Now 0.000 kW 6.138 kW 6.138 kW
Today 17.171 kWh (0.921 kW) 16.820 kWh (0.902 kW) -0.351 kWh (-0.019 kW)
  - This Week 17.171 kWh (22.106 kWh/day) 16.820 kWh (21.654 kWh/day) -0.351 kWh (-0.452 kWh/day)
  - This Month 34.109 kWh (19.193 kWh/day) 33.008 kWh (18.574 kWh/day) -1.101 kWh (-0.620 kWh/day)
  - This Year 5.612 MWh (18.353 kWh/day) 6.365 MWh (20.817 kWh/day) 0.753 MWh (2.464 kWh/day)
Yesterday 16.938 kWh (0.705 kW) 16.188 kWh (0.674 kW) -0.750 kWh (-0.031 kW)
Last 7 Days 84.554 kWh (12.079 kWh/day) 68.911 kWh (9.845 kWh/day) -15.643 kWh (-2.235 kWh/day)
Last 30 Days 448.063 kWh (14.935 kWh/day) 470.286 kWh (15.676 kWh/day) 22.223 kWh (0.741 kWh/day)
Last One Year 6.208 MWh (17.009 kWh/day) 7.413 MWh (20.310 kWh/day) 1.205 MWh (3.301 kWh/day)
Lifetime Since PTO 35.063 MWh (17.657 kW/day) 38.318 MWh (19.296 kW/day) 3.255 MWh (1.639 kW/day)
Lifetime Since Install 35.097 MWh 38.898 MWh 3.801 MWh
Voltage/Current 247.3 V / 0.0 A 247.3 V / 24.8 A 247.3 V / 24.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/02/2020 23:14 (10.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 17.518 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.282 1.242 0.284 3.157 0.000 kW
1.214 kWh
0.000 kW
7.283 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.277 1.190 0.280 3.049
03 - 202224****** IQ7+M [0] ---- 0.000 0.281 1.187 0.285 3.145
04 - 202232****** IQ7+ [0] ---- 0.000 0.280 1.184 0.281 3.099
05 - 202244****** IQ7+M [0] ---- 0.000 0.281 1.223 0.278 3.099
06 - 202245****** IQ7+M [0] ---- 0.000 0.279 1.257 0.280 3.145
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.298 1.480 0.266 3.302 0.000 kW
1.505 kWh
0.000 kW
7.523 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.298 1.415 0.252 3.129
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.557 0.269 3.439
10 - 202244****** IQ7+M [0] ---- 0.000 0.299 1.556 0.271 3.444
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.515 0.266 3.326
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.195 0.633 0.260 2.289 0.000 kW
0.678 kWh
0.000 kW
2.712 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.197 0.695 0.262 2.359
14 - 202216****** IQ7+ [0] ---- 0.000 0.197 0.698 0.265 2.410
15 - 202245****** IQ7+M [0] ---- 0.000 0.193 0.686 0.261 2.355
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.02 V Current/Power 178.11 A (10.156 kW)
Remain Capacity/Energy 587.4 Ah (30.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.4 % State Of Health 98.5 %
Run Time 1m to full Report Date 2020-11-02 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.02 V Cell (MIN/MAX) 3.555 V / 3.571 V (0.016 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 195.8 Ah (10.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.4 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-02 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.560 V 3.562 V 3.560 V 3.555 V 3.567 V 3.564 V 3.564 V 3.565 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.560 V 3.565 V 3.566 V 3.565 V 3.563 V 3.556 V 3.570 V 3.571 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -