Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.781 kW
08/26/2025 22:12 (1917 days) Production Consumption NET Usage
Now 0.000 kW 0.781 kW 0.781 kW
Today 24.392 kWh (1.098 kW) 17.437 kWh (0.785 kW) -6.955 kWh (-0.313 kW)
  - This Week 71.220 kWh (24.342 kWh/day) 62.748 kWh (21.447 kWh/day) -8.472 kWh (-2.896 kWh/day)
  - This Month 624.323 kWh (24.081 kWh/day) 747.330 kWh (28.826 kWh/day) 123.007 kWh (4.745 kWh/day)
  - This Year 4.382 MWh (18.418 kWh/day) 5.085 MWh (21.372 kWh/day) 0.703 MWh (2.954 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.833 MWh (17.640 kW/day) 37.037 MWh (19.311 kW/day) 3.204 MWh (1.671 kW/day)
Lifetime Since Install 33.867 MWh 37.617 MWh 3.750 MWh
Voltage/Current 252.5 V / 0.0 A 252.6 V / 3.1 A 252.5 V / 3.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/03/2020 21:18 (13.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.140 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.294 2.042 1.384 12.019 0.000 kW
1.974 kWh
0.000 kW
11.842 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.968 1.369 11.644
03 - 202224****** IQ7+M [0] ---- 0.000 0.294 1.990 1.394 11.775
04 - 202232****** IQ7+ [0] ---- 0.000 0.295 2.016 1.387 11.871
05 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.852 1.375 11.009
06 - 202245****** IQ7+M [0] ---- 0.000 0.292 1.974 1.372 11.692
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.295 1.900 1.371 10.883 0.000 kW
1.896 kWh
0.000 kW
9.481 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.295 1.890 1.415 11.296
09 - 202217****** IQ7+ [0] ---- 0.000 0.294 1.893 1.386 11.025
10 - 202244****** IQ7+M [0] ---- 0.000 0.295 1.903 1.427 11.390
11 - 202224****** IQ7+M [0] ---- 0.000 0.295 1.894 1.422 11.401
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.248 1.984 1.123 11.432 0.000 kW
1.954 kWh
0.000 kW
7.817 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.246 1.912 1.079 10.986
14 - 202216****** IQ7+ [0] ---- 0.000 0.248 1.976 1.140 11.446
15 - 202245****** IQ7+M [0] ---- 0.000 0.243 1.945 1.120 11.258
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.61 V Current/Power 179.92 A (10.366 kW)
Remain Capacity/Energy 575.1 Ah (29.4 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.6 % State Of Health 96.2 %
Run Time - to full Report Date 2020-08-03 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.61 V Cell (MIN/MAX) 3.586 V / 3.606 V (0.020 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 191.7 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.6 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-03 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.600 V 3.596 V 3.601 V 3.597 V 3.603 V 3.599 V 3.603 V 3.605 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.597 V 3.595 V 3.601 V 3.586 V 3.605 V 3.606 V 3.605 V 3.606 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -