Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.301 kW
08/27/2025 01:14 (1918 days) Production Consumption NET Usage
Now 0.000 kW 0.301 kW 0.301 kW
Today 0.000 kWh (0.000 kW) 0.401 kWh (0.321 kW) 0.401 kWh (0.321 kW)
  - This Week 71.220 kWh (23.333 kWh/day) 64.335 kWh (21.078 kWh/day) -6.885 kWh (-2.256 kWh/day)
  - This Month 624.323 kWh (23.964 kWh/day) 748.917 kWh (28.747 kWh/day) 124.594 kWh (4.782 kWh/day)
  - This Year 4.382 MWh (18.408 kWh/day) 5.086 MWh (21.367 kWh/day) 0.704 MWh (2.959 kWh/day)
Yesterday 24.392 kWh (1.016 kW) 18.623 kWh (0.776 kW) -5.769 kWh (-0.240 kW)
Last 7 Days 151.821 kWh (21.689 kWh/day) 178.457 kWh (25.494 kWh/day) 26.636 kWh (3.805 kWh/day)
Last 30 Days 719.386 kWh (23.979 kWh/day) 906.653 kWh (30.221 kWh/day) 187.267 kWh (6.242 kWh/day)
Last One Year 6.301 MWh (17.263 kWh/day) 6.986 MWh (19.139 kWh/day) 0.685 MWh (1.876 kWh/day)
Lifetime Since PTO 33.833 MWh (17.639 kW/day) 37.038 MWh (19.310 kW/day) 3.206 MWh (1.671 kW/day)
Lifetime Since Install 33.867 MWh 37.618 MWh 3.752 MWh
Voltage/Current 253.8 V / 0.0 A 253.7 V / 1.2 A 253.8 V / 1.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/26/2020 23:37 (14.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.690 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.292 2.171 1.740 12.013 0.000 kW
2.101 kWh
0.000 kW
12.609 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.288 2.094 1.679 11.679
03 - 202224****** IQ7+M [0] ---- 0.000 0.290 2.113 1.683 11.753
04 - 202232****** IQ7+ [0] ---- 0.000 0.289 2.126 1.709 11.804
05 - 202244****** IQ7+M [0] ---- 0.000 0.289 1.998 1.525 10.922
06 - 202245****** IQ7+M [0] ---- 0.000 0.289 2.106 1.693 11.737
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.291 1.975 1.537 10.776 0.000 kW
2.025 kWh
0.000 kW
10.124 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.292 2.036 1.576 11.048
09 - 202217****** IQ7+ [0] ---- 0.000 0.289 2.010 1.550 10.898
10 - 202244****** IQ7+M [0] ---- 0.000 0.290 2.053 1.591 11.145
11 - 202224****** IQ7+M [0] ---- 0.000 0.289 2.050 1.583 11.122
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.282 2.020 1.813 11.739 0.000 kW
1.989 kWh
0.000 kW
7.957 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.283 1.943 1.763 11.424
14 - 202216****** IQ7+ [0] ---- 0.000 0.282 2.016 1.816 11.763
15 - 202245****** IQ7+M [0] ---- 0.000 0.276 1.978 1.798 11.590
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.61 V Current/Power 179.84 A (10.361 kW)
Remain Capacity/Energy 576.9 Ah (29.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.9 % State Of Health 96.2 %
Run Time - to full Report Date 2020-07-26 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.61 V Cell (MIN/MAX) 3.583 V / 3.606 V (0.023 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 192.3 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.9 % State Of Health 96.2 %
Temperature 26.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-07-26 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.598 V 3.583 V 3.600 V 3.598 V 3.601 V 3.602 V 3.600 V 3.602 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.599 V 3.599 V 3.602 V 3.601 V 3.602 V 3.606 V 3.606 V 3.606 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -