Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.106 kW
02/01/2026 16:32 (2076 days) Production Consumption NET Usage
Now 0.573 kW 0.467 kW -0.106 kW
Today 19.751 kWh (1.192 kW) 10.731 kWh (0.648 kW) -9.020 kWh (-0.544 kW)
  - This Week 19.751 kWh (28.603 kWh/day) 10.731 kWh (15.540 kWh/day) -9.020 kWh (-13.063 kWh/day)
  - This Month 19.751 kWh (28.603 kWh/day) 10.731 kWh (15.540 kWh/day) -9.020 kWh (-13.063 kWh/day)
  - This Year 0.265 MWh (8.368 kWh/day) 0.594 MWh (18.741 kWh/day) 0.329 MWh (10.374 kWh/day)
Yesterday 17.942 kWh (0.748 kW) 16.650 kWh (0.694 kW) -1.292 kWh (-0.054 kW)
Last 7 Days 59.276 kWh (9.395 kWh/day) 99.547 kWh (15.778 kWh/day) 40.271 kWh (6.383 kWh/day)
Last 30 Days 228.983 kWh (7.813 kWh/day) 563.359 kWh (19.221 kWh/day) 334.376 kWh (11.409 kWh/day)
Last One Year 6.078 MWh (16.682 kWh/day) 7.494 MWh (20.571 kWh/day) 1.417 MWh (3.889 kWh/day)
Lifetime Since PTO 35.831 MWh (17.253 kW/day) 40.105 MWh (19.312 kW/day) 4.275 MWh (2.058 kW/day)
Lifetime Since Install 35.865 MWh 40.685 MWh 4.821 MWh
Voltage/Current 251.3 V / 2.3 A 251.3 V / 1.9 A 251.3 V / -0.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/30/2025 23:18 (14.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.069 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.285 1.748 2.005 11.437 0.000 kW
1.687 kWh
0.000 kW
10.122 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.278 1.656 1.867 10.770
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.710 1.913 11.047
04 - 202232****** IQ7+ [5] VCOP 0.000 0.292 1.745 1.961 11.254
05 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.555 1.729 9.978
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.708 1.925 11.085
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.286 1.603 1.827 10.563 0.000 kW
1.607 kWh
0.000 kW
8.036 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.599 1.797 10.293
09 - 202217****** IQ7+ [5] VCOP 0.000 0.286 1.606 1.808 10.430
10 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.608 1.838 10.580
11 - 202224****** IQ7+M [5] VCOP 0.000 0.290 1.620 1.868 10.652
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.229 1.674 1.809 10.804 0.000 kW
1.728 kWh
0.000 kW
6.912 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.235 1.707 1.819 10.837
14 - 202216****** IQ7+ [0] ---- 0.000 0.236 1.758 1.882 11.326
15 - 202245****** IQ7+M [0] V--- 0.000 0.239 1.773 1.887 11.416
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 0.41 V Voltage Charge 52.83 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 32.8 °C / 30.1 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-07-30 23:58
voltage in/out power and energy

Battery History
Voltage 53.11 V Current/Power -6.35 A (-0.337 kW)
Remain Capacity/Energy 387.0 Ah (19.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 65.3 % State Of Health 98.9 %
Run Time 2d 12h 56m to empty Report Date 2025-07-30 23:56
voltag, current for each battery pack voltage, current, and SOC