Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.798 kW
07/10/2025 20:32 (1870 days) Production Consumption NET Usage
Now 0.000 kW 0.798 kW 0.798 kW
Today 16.102 kWh (0.782 kW) 24.500 kWh (1.191 kW) 8.398 kWh (0.408 kW)
  - This Week 115.697 kWh (23.819 kWh/day) 216.577 kWh (44.587 kWh/day) 100.880 kWh (20.768 kWh/day)
  - This Month 245.406 kWh (24.897 kWh/day) 385.303 kWh (39.089 kWh/day) 139.897 kWh (14.193 kWh/day)
  - This Year 3.275 MWh (17.160 kWh/day) 3.513 MWh (18.404 kWh/day) 0.237 MWh (1.244 kWh/day)
Yesterday 25.046 kWh (1.044 kW) 40.411 kWh (1.684 kW) 15.365 kWh (0.640 kW)
Last 7 Days 187.533 kWh (26.791 kWh/day) 299.677 kWh (42.813 kWh/day) 112.144 kWh (16.021 kWh/day)
Last 30 Days 652.855 kWh (21.763 kWh/day) 970.553 kWh (32.353 kWh/day) 317.698 kWh (10.590 kWh/day)
Last One Year 6.296 MWh (17.249 kWh/day) 6.482 MWh (17.760 kWh/day) 0.186 MWh (0.511 kWh/day)
Lifetime Since PTO 32.726 MWh (17.493 kW/day) 35.465 MWh (18.956 kW/day) 2.739 MWh (1.464 kW/day)
Lifetime Since Install 32.760 MWh 36.044 MWh 3.285 MWh
Voltage/Current 250.8 V / 0.0 A 250.6 V / 3.2 A 250.7 V / 3.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/06/2020 22:49 (14.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.023 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] ---- 0.000 0.290 1.854 0.696 11.958 0.000 kW
1.776 kWh
0.000 kW
10.653 kWh
02 - 202244****** IQ7+M [5] ---- 0.000 0.287 1.785 0.685 11.587
03 - 202224****** IQ7+M [5] ---- 0.000 0.289 1.784 0.700 11.573
04 - 202232****** IQ7+ [5] ---- 0.000 0.288 1.786 0.688 11.617
05 - 202244****** IQ7+M [5] ---- 0.000 0.287 1.634 0.674 10.725
06 - 202245****** IQ7+M [5] ---- 0.000 0.286 1.811 0.685 11.606
front 07 - 202206****** IQ7+ [5] ---- 0.000 0.290 1.524 0.618 10.537 0.000 kW
1.612 kWh
0.000 kW
8.058 kWh
08 - 202245****** IQ7+M [5] ---- 0.000 0.291 1.629 0.617 10.820
09 - 202217****** IQ7+ [5] -C-- 0.000 0.290 1.581 0.627 10.767
10 - 202244****** IQ7+M [5] ---- 0.000 0.291 1.659 0.633 10.928
11 - 202224****** IQ7+M [5] ---- 0.000 0.290 1.666 0.627 10.913
back 12 - 202211****** IQ7+ [5] ---- 0.000 0.261 1.850 0.678 12.180 0.000 kW
1.828 kWh
0.000 kW
7.312 kWh
13 - 202223****** IQ7+ [5] ---- 0.000 0.262 1.795 0.683 11.884
14 - 202216****** IQ7+ [5] ---- 0.000 0.262 1.848 0.694 12.136
15 - 202245****** IQ7+M [5] ---- 0.000 0.258 1.818 0.683 11.946
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 56.03 V Current/Power 175.11 A (9.811 kW)
Remain Capacity/Energy 570.0 Ah (29.2 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 98.8 % State Of Health 96.2 %
Run Time 2m to full Report Date 2020-06-06 23:16
voltag, current for each battery pack voltage, current, and SOC

Voltage 56.03 V Cell (MIN/MAX) 3.495 V / 3.505 V (0.010 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 190.0 Ah (9.7 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 98.8 % State Of Health 96.2 %
Temperature 24.5 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-06 23:16
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.501 V 3.495 V 3.503 V 3.501 V 3.504 V 3.502 V 3.505 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.501 V 3.498 V 3.500 V 3.505 V 3.502 V 3.502 V 3.505 V 3.503 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -