Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.527 kW
07/10/2025 15:43 (1870 days) Production Consumption NET Usage
Now 1.240 kW 0.713 kW -0.527 kW
Today 12.127 kWh (0.769 kW) 15.776 kWh (1.001 kW) 3.649 kWh (0.231 kW)
  - This Week 111.722 kWh (23.991 kWh/day) 207.853 kWh (44.635 kWh/day) 96.131 kWh (20.643 kWh/day)
  - This Month 241.431 kWh (25.002 kWh/day) 376.579 kWh (38.998 kWh/day) 135.148 kWh (13.996 kWh/day)
  - This Year 3.271 MWh (17.157 kWh/day) 3.504 MWh (18.378 kWh/day) 0.233 MWh (1.220 kWh/day)
Yesterday 25.046 kWh (1.044 kW) 40.411 kWh (1.684 kW) 15.365 kWh (0.640 kW)
Last 7 Days 187.533 kWh (26.791 kWh/day) 299.677 kWh (42.813 kWh/day) 112.144 kWh (16.021 kWh/day)
Last 30 Days 652.855 kWh (21.763 kWh/day) 970.553 kWh (32.353 kWh/day) 317.698 kWh (10.590 kWh/day)
Last One Year 6.296 MWh (17.249 kWh/day) 6.482 MWh (17.760 kWh/day) 0.186 MWh (0.511 kWh/day)
Lifetime Since PTO 32.722 MWh (17.492 kW/day) 35.456 MWh (18.954 kW/day) 2.734 MWh (1.461 kW/day)
Lifetime Since Install 32.756 MWh 36.036 MWh 3.280 MWh
Voltage/Current 248.2 V / 5.0 A 248.3 V / 2.9 A 248.2 V / -2.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/31/2020 22:48 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 33.904 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.378 2.292 4.912 0.000 kW
2.275 kWh
0.000 kW
13.650 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.300 2.314 2.234 4.816
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.290 2.236 4.870
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.317 2.243 4.854
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 2.098 2.069 4.645
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.253 2.241 4.833
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.992 2.068 4.489 0.000 kW
2.100 kWh
0.000 kW
10.502 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 2.119 2.123 4.638
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 2.069 2.108 4.600
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.153 2.122 4.677
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.169 2.115 4.667
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.288 2.488 2.221 4.522 0.000 kW
2.438 kWh
0.000 kW
9.752 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.287 2.408 2.154 4.396
14 - 202216****** IQ7+ [5] VCOP 0.000 0.285 2.445 2.202 4.537
15 - 202245****** IQ7+M [5] VCOP 0.000 0.279 2.412 2.168 4.482
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 56.03 V Current/Power 175.09 A (9.811 kW)
Remain Capacity/Energy 574.2 Ah (29.4 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.5 % State Of Health 96.2 %
Run Time 1m to full Report Date 2020-05-31 23:17
voltag, current for each battery pack voltage, current, and SOC

Voltage 56.03 V Cell (MIN/MAX) 3.494 V / 3.506 V (0.012 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 191.4 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.5 % State Of Health 96.2 %
Temperature 24.0 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-05-31 23:17
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.501 V 3.494 V 3.503 V 3.503 V 3.498 V 3.503 V 3.505 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.502 V 3.502 V 3.501 V 3.503 V 3.506 V 3.502 V 3.505 V 3.504 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -