Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.403 kW
08/26/2025 23:20 (1917 days) Production Consumption NET Usage
Now 0.000 kW 0.403 kW 0.403 kW
Today 24.392 kWh (1.045 kW) 18.405 kWh (0.788 kW) -5.987 kWh (-0.256 kW)
  - This Week 71.220 kWh (23.957 kWh/day) 63.716 kWh (21.433 kWh/day) -7.504 kWh (-2.524 kWh/day)
  - This Month 624.323 kWh (24.037 kWh/day) 748.298 kWh (28.811 kWh/day) 123.975 kWh (4.773 kWh/day)
  - This Year 4.382 MWh (18.414 kWh/day) 5.086 MWh (21.372 kWh/day) 0.704 MWh (2.958 kWh/day)
Yesterday 27.655 kWh (1.153 kW) 22.480 kWh (0.937 kW) -5.175 kWh (-0.216 kW)
Last 7 Days 156.753 kWh (22.394 kWh/day) 180.948 kWh (25.850 kWh/day) 24.195 kWh (3.457 kWh/day)
Last 30 Days 706.798 kWh (23.559 kWh/day) 918.722 kWh (30.623 kWh/day) 211.924 kWh (7.064 kWh/day)
Last One Year 6.301 MWh (17.262 kWh/day) 6.982 MWh (19.128 kWh/day) 0.681 MWh (1.866 kWh/day)
Lifetime Since PTO 33.833 MWh (17.640 kW/day) 37.038 MWh (19.311 kW/day) 3.205 MWh (1.671 kW/day)
Lifetime Since Install 33.867 MWh 37.618 MWh 3.751 MWh
Voltage/Current 252.5 V / 0.0 A 252.4 V / 1.6 A 252.5 V / 1.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/09/2020 23:28 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.082 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.284 2.186 1.301 11.689 0.000 kW
2.162 kWh
0.000 kW
12.970 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.282 2.156 1.287 11.382
03 - 202224****** IQ7+M [0] ---- 0.000 0.285 2.187 1.300 11.423
04 - 202232****** IQ7+ [0] ---- 0.000 0.288 2.190 1.295 11.435
05 - 202244****** IQ7+M [0] ---- 0.000 0.283 2.091 1.244 10.666
06 - 202245****** IQ7+M [0] ---- 0.000 0.281 2.161 1.285 11.444
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.278 1.979 1.139 10.289 0.000 kW
2.053 kWh
0.000 kW
10.264 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.277 2.076 1.171 10.575
09 - 202217****** IQ7+ [0] ---- 0.000 0.277 2.021 1.153 10.445
10 - 202244****** IQ7+M [0] ---- 0.000 0.276 2.089 1.195 10.658
11 - 202224****** IQ7+M [0] ---- 0.000 0.275 2.098 1.186 10.619
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.272 1.983 1.269 11.443 0.000 kW
1.962 kWh
0.000 kW
7.848 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.273 1.903 1.266 11.255
14 - 202216****** IQ7+ [0] ---- 0.000 0.274 1.996 1.286 11.502
15 - 202245****** IQ7+M [0] ---- 0.000 0.270 1.967 1.272 11.312
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.61 V Current/Power 179.97 A (10.367 kW)
Remain Capacity/Energy 575.4 Ah (29.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.7 % State Of Health 96.2 %
Run Time - to full Report Date 2020-07-09 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.61 V Cell (MIN/MAX) 3.588 V / 3.607 V (0.019 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 191.8 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.7 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 23
MOSFET CFET = ON, DFET = ON Reported 2020-07-09 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.598 V 3.593 V 3.599 V 3.599 V 3.603 V 3.599 V 3.603 V 3.604 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.598 V 3.602 V 3.602 V 3.602 V 3.602 V 3.602 V 3.588 V 3.607 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -