Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.648 kW
11/03/2025 08:55 (1986 days) Production Consumption NET Usage
Now 0.917 kW 0.269 kW -0.648 kW
Today 0.924 kWh (0.103 kW) 2.381 kWh (0.266 kW) 1.457 kWh (0.163 kW)
  - This Week 18.095 kWh (13.186 kWh/day) 28.698 kWh (20.913 kWh/day) 10.603 kWh (7.727 kWh/day)
  - This Month 35.033 kWh (14.766 kWh/day) 44.886 kWh (18.918 kWh/day) 9.853 kWh (4.153 kWh/day)
  - This Year 5.613 MWh (18.321 kWh/day) 6.377 MWh (20.815 kWh/day) 0.764 MWh (2.495 kWh/day)
Yesterday 17.171 kWh (0.716 kW) 26.317 kWh (1.097 kW) 9.146 kWh (0.381 kW)
Last 7 Days 86.148 kWh (12.307 kWh/day) 98.955 kWh (14.137 kWh/day) 12.807 kWh (1.830 kWh/day)
Last 30 Days 441.432 kWh (14.715 kWh/day) 484.805 kWh (16.161 kWh/day) 43.373 kWh (1.446 kWh/day)
Last One Year 6.208 MWh (17.008 kWh/day) 7.431 MWh (20.358 kWh/day) 1.223 MWh (3.350 kWh/day)
Lifetime Since PTO 35.064 MWh (17.652 kW/day) 38.330 MWh (19.296 kW/day) 3.266 MWh (1.644 kW/day)
Lifetime Since Install 35.098 MWh 38.910 MWh 3.812 MWh
Voltage/Current 249.1 V / 3.7 A 249.0 V / 1.1 A 249.1 V / -2.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/12/2020 22:14 (12.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.239 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.603 1.245 10.228 0.000 kW
1.596 kWh
0.000 kW
9.576 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.597 1.233 10.141
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.633 1.260 10.347
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.624 1.246 10.319
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.561 1.227 9.847
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.558 1.229 9.850
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.646 1.334 10.262 0.000 kW
1.647 kWh
0.000 kW
8.236 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.599 1.343 10.003
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.639 1.316 10.182
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.680 1.389 10.498
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.671 1.372 10.446
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.276 1.363 0.922 8.900 0.000 kW
1.357 kWh
0.000 kW
5.428 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.277 1.337 0.891 8.743
14 - 202216****** IQ7+ [5] VCOP 0.000 0.277 1.376 0.937 8.958
15 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.352 0.918 8.830
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.60 V Current/Power 179.92 A (10.364 kW)
Remain Capacity/Energy 581.4 Ah (29.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 98.4 % State Of Health 98.5 %
Run Time 3m to full Report Date 2020-09-12 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.