Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.608 kW
08/27/2025 02:30 (1918 days) Production Consumption NET Usage
Now 0.000 kW 0.608 kW 0.608 kW
Today 0.000 kWh (0.000 kW) 1.148 kWh (0.457 kW) 1.148 kWh (0.457 kW)
  - This Week 71.220 kWh (22.939 kWh/day) 65.082 kWh (20.962 kWh/day) -6.138 kWh (-1.977 kWh/day)
  - This Month 624.323 kWh (23.916 kWh/day) 749.664 kWh (28.717 kWh/day) 125.341 kWh (4.801 kWh/day)
  - This Year 4.382 MWh (18.404 kWh/day) 5.087 MWh (21.366 kWh/day) 0.705 MWh (2.962 kWh/day)
Yesterday 24.392 kWh (1.016 kW) 18.623 kWh (0.776 kW) -5.769 kWh (-0.240 kW)
Last 7 Days 151.821 kWh (21.689 kWh/day) 178.457 kWh (25.494 kWh/day) 26.636 kWh (3.805 kWh/day)
Last 30 Days 719.386 kWh (23.979 kWh/day) 906.653 kWh (30.221 kWh/day) 187.267 kWh (6.242 kWh/day)
Last One Year 6.301 MWh (17.263 kWh/day) 6.986 MWh (19.139 kWh/day) 0.685 MWh (1.876 kWh/day)
Lifetime Since PTO 33.833 MWh (17.639 kW/day) 37.039 MWh (19.310 kW/day) 3.206 MWh (1.672 kW/day)
Lifetime Since Install 33.867 MWh 37.619 MWh 3.752 MWh
Voltage/Current 253.6 V / 0.0 A 253.7 V / 2.4 A 253.6 V / 2.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/02/2020 23:00 (14.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.602 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.293 2.084 1.666 11.483 0.000 kW
1.989 kWh
0.000 kW
11.933 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.291 2.010 1.614 11.089
03 - 202224****** IQ7+M [0] ---- 0.000 0.291 1.998 1.601 11.033
04 - 202232****** IQ7+ [0] ---- 0.000 0.292 2.011 1.616 11.078
05 - 202244****** IQ7+M [0] ---- 0.000 0.290 1.798 1.456 10.126
06 - 202245****** IQ7+M [0] ---- 0.000 0.292 2.032 1.628 11.216
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.291 1.785 1.429 9.925 0.000 kW
1.827 kWh
0.000 kW
9.135 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.291 1.843 1.505 10.245
09 - 202217****** IQ7+ [0] ---- 0.000 0.289 1.806 1.484 10.134
10 - 202244****** IQ7+M [0] ---- 0.000 0.290 1.853 1.521 10.374
11 - 202224****** IQ7+M [0] ---- 0.000 0.289 1.849 1.513 10.331
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.259 2.161 1.631 12.036 0.000 kW
2.134 kWh
0.000 kW
8.535 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.257 2.117 1.596 11.814
14 - 202216****** IQ7+ [0] ---- 0.000 0.259 2.151 1.642 12.072
15 - 202245****** IQ7+M [0] ---- 0.000 0.254 2.106 1.617 11.866
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.25 V Current/Power 166.27 A (8.853 kW)
Remain Capacity/Energy 567.7 Ah (29.1 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 98.3 % State Of Health 96.2 %
Run Time 3m to full Report Date 2020-07-02 23:43
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.25 V Cell (MIN/MAX) 3.322 V / 3.332 V (0.010 V)
Current/Power -0.50 A (-26 W) Runtime 15d 21h 30m to empty
Remain Capacity/Energy 189.2 Ah (9.7 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 98.3 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-07-02 23:43
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.322 V 3.323 V 3.324 V 3.324 V 3.326 V 3.326 V 3.327 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.328 V 3.328 V 3.329 V 3.330 V 3.330 V 3.332 V 3.331 V 3.332 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -