Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.092 kW
11/03/2025 15:48 (1986 days) Production Consumption NET Usage
Now 0.286 kW 0.378 kW 0.092 kW
Today 6.518 kWh (0.412 kW) 5.782 kWh (0.365 kW) -0.736 kWh (-0.046 kW)
  - This Week 23.689 kWh (14.281 kWh/day) 32.099 kWh (19.351 kWh/day) 8.410 kWh (5.070 kWh/day)
  - This Month 40.627 kWh (15.278 kWh/day) 48.287 kWh (18.159 kWh/day) 7.660 kWh (2.881 kWh/day)
  - This Year 5.619 MWh (18.322 kWh/day) 6.381 MWh (20.807 kWh/day) 0.762 MWh (2.485 kWh/day)
Yesterday 17.171 kWh (0.716 kW) 26.317 kWh (1.097 kW) 9.146 kWh (0.381 kW)
Last 7 Days 86.148 kWh (12.307 kWh/day) 98.955 kWh (14.137 kWh/day) 12.807 kWh (1.830 kWh/day)
Last 30 Days 441.432 kWh (14.715 kWh/day) 484.805 kWh (16.161 kWh/day) 43.373 kWh (1.446 kWh/day)
Last One Year 6.208 MWh (17.008 kWh/day) 7.431 MWh (20.358 kWh/day) 1.223 MWh (3.350 kWh/day)
Lifetime Since PTO 35.069 MWh (17.652 kW/day) 38.333 MWh (19.295 kW/day) 3.264 MWh (1.643 kW/day)
Lifetime Since Install 35.103 MWh 38.913 MWh 3.810 MWh
Voltage/Current 249.3 V / 1.1 A 249.3 V / 1.5 A 249.3 V / 0.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/07/2020 22:25 (12.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.265 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.278 1.600 1.541 9.371 0.000 kW
1.584 kWh
0.000 kW
9.504 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.277 1.592 1.529 9.262
03 - 202224****** IQ7+M [5] VCOP 0.000 0.281 1.630 1.564 9.424
04 - 202232****** IQ7+ [5] VCOP 0.000 0.280 1.634 1.566 9.379
05 - 202244****** IQ7+M [5] VCOP 0.000 0.280 1.528 1.458 8.991
06 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.520 1.458 9.031
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.574 1.486 9.188 0.000 kW
1.562 kWh
0.000 kW
7.811 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.483 1.420 9.033
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.579 1.482 9.141
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.591 1.523 9.374
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.582 1.517 9.343
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.216 1.489 1.461 8.213 0.000 kW
1.488 kWh
0.000 kW
5.950 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.215 1.480 1.448 8.063
14 - 202216****** IQ7+ [5] VCOP 0.000 0.213 1.499 1.464 8.257
15 - 202245****** IQ7+M [5] VCOP 0.000 0.210 1.483 1.442 8.124
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.62 V Current/Power 179.87 A (10.364 kW)
Remain Capacity/Energy 584.7 Ah (29.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 98.9 % State Of Health 98.5 %
Run Time 2m to full Report Date 2020-09-07 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.