Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.445 kW
08/27/2025 04:05 (1918 days) Production Consumption NET Usage
Now 0.000 kW 0.445 kW 0.445 kW
Today 0.000 kWh (0.000 kW) 1.856 kWh (0.453 kW) 1.856 kWh (0.453 kW)
  - This Week 71.220 kWh (22.460 kWh/day) 65.790 kWh (20.748 kWh/day) -5.430 kWh (-1.712 kWh/day)
  - This Month 624.323 kWh (23.855 kWh/day) 750.372 kWh (28.672 kWh/day) 126.049 kWh (4.816 kWh/day)
  - This Year 4.382 MWh (18.399 kWh/day) 5.088 MWh (21.363 kWh/day) 0.706 MWh (2.964 kWh/day)
Yesterday 24.392 kWh (1.016 kW) 18.623 kWh (0.776 kW) -5.769 kWh (-0.240 kW)
Last 7 Days 151.821 kWh (21.689 kWh/day) 178.457 kWh (25.494 kWh/day) 26.636 kWh (3.805 kWh/day)
Last 30 Days 719.386 kWh (23.979 kWh/day) 906.653 kWh (30.221 kWh/day) 187.267 kWh (6.242 kWh/day)
Last One Year 6.301 MWh (17.263 kWh/day) 6.986 MWh (19.139 kWh/day) 0.685 MWh (1.876 kWh/day)
Lifetime Since PTO 33.833 MWh (17.638 kW/day) 37.040 MWh (19.310 kW/day) 3.207 MWh (1.672 kW/day)
Lifetime Since Install 33.867 MWh 37.620 MWh 3.753 MWh
Voltage/Current 254.6 V / 0.0 A 254.4 V / 1.7 A 254.5 V / 1.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/26/2020 22:53 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.740 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.986 1.989 14.114 0.000 kW
1.914 kWh
0.000 kW
11.485 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.929 1.925 13.690
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.919 1.915 13.655
04 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.923 1.932 13.744
05 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.782 1.730 12.541
06 - 202245****** IQ7+M [0] ---- 0.000 0.298 1.946 1.948 13.865
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 1.746 1.666 12.315 0.000 kW
1.798 kWh
0.000 kW
8.992 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.809 1.758 12.837
09 - 202217****** IQ7+ [0] ---- 0.000 0.298 1.803 1.718 12.631
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.820 1.783 12.964
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.813 1.783 12.981
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.296 2.088 2.036 14.072 0.000 kW
2.066 kWh
0.000 kW
8.264 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.296 2.046 1.977 13.661
14 - 202216****** IQ7+ [0] ---- 0.000 0.295 2.086 2.035 14.112
15 - 202245****** IQ7+M [0] ---- 0.000 0.292 2.043 2.003 13.873
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.23 V Current/Power 166.25 A (8.850 kW)
Remain Capacity/Energy 497.1 Ah (25.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 86.1 % State Of Health 96.2 %
Run Time 28m to full Report Date 2020-06-26 23:53
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.23 V Cell (MIN/MAX) 3.321 V / 3.331 V (0.010 V)
Current/Power -0.48 A (-25 W) Runtime 14d 6h 21m to empty
Remain Capacity/Energy 165.7 Ah (8.5 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 86.1 % State Of Health 96.2 %
Temperature 24.5 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-26 23:53
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.321 V 3.323 V 3.323 V 3.323 V 3.324 V 3.325 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.327 V 3.328 V 3.328 V 3.329 V 3.330 V 3.331 V 3.331 V 3.331 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -