Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.328 kW
05/21/2026 03:09 (2185 days) Production Consumption NET Usage
Now 0.000 kW 0.328 kW 0.328 kW
Today 0.000 kWh (0.000 kW) 1.716 kWh (0.539 kW) 1.716 kWh (0.539 kW)
  - This Week 116.795 kWh (28.264 kWh/day) 131.400 kWh (31.798 kWh/day) 14.605 kWh (3.534 kWh/day)
  - This Month 518.611 kWh (25.761 kWh/day) 331.122 kWh (16.448 kWh/day) -187.489 kWh (-9.313 kWh/day)
  - This Year 2.472 MWh (17.638 kWh/day) 2.391 MWh (17.061 kWh/day) -0.081 MWh (-0.577 kWh/day)
Yesterday 25.684 kWh (1.070 kW) 42.704 kWh (1.779 kW) 17.020 kWh (0.709 kW)
Last 7 Days 192.239 kWh (27.463 kWh/day) 161.461 kWh (23.066 kWh/day) -30.778 kWh (-4.397 kWh/day)
Last 30 Days (04/21/2026) 722.358 kWh (24.079 kWh/day) 413.638 kWh (13.788 kWh/day) -308.720 kWh (-10.291 kWh/day)
Last One Year 6.363 MWh (17.433 kWh/day) 7.796 MWh (21.359 kWh/day) 1.433 MWh (3.927 kWh/day)
Lifetime Since PTO 38.037 MWh (17.407 kW/day) 41.902 MWh (19.176 kW/day) 3.864 MWh (1.768 kW/day)
Lifetime Since Install 38.071 MWh 42.482 MWh 4.410 MWh
Voltage/Current 251.2 V / 0.0 A 251.3 V / 1.3 A 251.3 V / 1.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/20/2021 23:20 (11.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.401 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.298 2.038 2.036 9.067 0.000 kW
1.992 kWh
0.000 kW
11.952 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.288 1.995 2.010 8.846
03 - 202224****** IQ7+M [0] ---- 0.000 0.294 2.033 2.050 9.058
04 - 202232****** IQ7+ [0] ---- 0.000 0.293 2.025 2.044 9.021
05 - 202244****** IQ7+M [0] ---- 0.000 0.289 1.936 1.956 8.641
06 - 202245****** IQ7+M [0] ---- 0.000 0.288 1.926 1.947 8.654
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.301 2.099 2.092 9.138 0.000 kW
2.081 kWh
0.000 kW
10.406 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.298 1.936 1.956 8.511
09 - 202217****** IQ7+ [0] ---- 0.000 0.300 2.092 2.093 9.209
10 - 202244****** IQ7+M [0] ---- 0.000 0.301 2.142 2.142 9.370
11 - 202224****** IQ7+M [0] ---- 0.000 0.300 2.137 2.133 9.314
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.224 1.531 1.547 6.982 0.000 kW
1.511 kWh
0.000 kW
6.043 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.220 1.479 1.497 6.835
14 - 202216****** IQ7+ [0] ---- 0.000 0.221 1.532 1.555 7.035
15 - 202245****** IQ7+M [0] ---- 0.000 0.217 1.501 1.526 6.896
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 55.05 V Current/Power 0.00 A (0 W)
Remain Capacity/Energy 591.0 Ah (30.3 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 100.0 % State Of Health 98.5 %
Run Time Stand-by Report Date 2021-03-20 23:57
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.