Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 3.192 kW
03/23/2026 17:31 (2126 days) Production Consumption NET Usage
Now 0.502 kW 3.694 kW 3.192 kW
Today 10.014 kWh (0.571 kW) 9.548 kWh (0.544 kW) -0.466 kWh (-0.027 kW)
  - This Week 32.762 kWh (18.935 kWh/day) 21.854 kWh (12.630 kWh/day) -10.908 kWh (-6.304 kWh/day)
  - This Month 406.749 kWh (17.895 kWh/day) 358.873 kWh (15.788 kWh/day) -47.876 kWh (-2.106 kWh/day)
  - This Year 1.041 MWh (12.733 kWh/day) 1.459 MWh (17.848 kWh/day) 0.418 MWh (5.115 kWh/day)
Yesterday 22.748 kWh (0.949 kW) 12.306 kWh (0.513 kW) -10.442 kWh (-0.435 kW)
Last 7 Days 154.960 kWh (22.137 kWh/day) 132.985 kWh (18.998 kWh/day) -21.975 kWh (-3.139 kWh/day)
Last 30 Days (02/21/2026) 487.665 kWh (16.256 kWh/day) 459.312 kWh (15.310 kWh/day) -28.353 kWh (-0.945 kWh/day)
Last One Year 6.064 MWh (16.614 kWh/day) 7.893 MWh (21.626 kWh/day) 1.829 MWh (5.012 kWh/day)
Lifetime Since PTO 36.606 MWh (17.213 kW/day) 40.969 MWh (19.264 kW/day) 4.363 MWh (2.052 kW/day)
Lifetime Since Install 36.640 MWh 41.549 MWh 4.909 MWh
Voltage/Current 249.9 V / 2.0 A 250.0 V / 14.8 A 250.0 V / 12.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/12/2021 22:07 (9.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.816 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.238 0.996 0.389 5.159 0.000 kW
0.962 kWh
0.000 kW
5.775 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.230 0.939 0.354 4.788
03 - 202224****** IQ7+M [5] VCOP 0.000 0.236 0.934 0.377 4.815
04 - 202232****** IQ7+ [5] VCOP 0.000 0.236 0.900 0.382 4.657
05 - 202244****** IQ7+M [5] VCOP 0.000 0.233 0.997 0.345 5.130
06 - 202245****** IQ7+M [5] VCOP 0.000 0.233 1.009 0.365 5.246
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.291 1.243 0.375 6.250 0.000 kW
1.246 kWh
0.000 kW
6.230 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.290 1.092 0.369 5.451
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.332 0.382 6.705
10 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.330 0.386 6.646
11 - 202224****** IQ7+M [5] VCOP 0.000 0.291 1.234 0.374 6.170
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.094 0.415 0.336 2.659 0.000 kW
0.453 kWh
0.000 kW
1.812 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.108 0.473 0.339 2.916
14 - 202216****** IQ7+ [5] VCOP 0.000 0.109 0.469 0.345 2.914
15 - 202245****** IQ7+M [5] VCOP 0.000 0.106 0.455 0.337 2.839
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.74 V Current/Power 167.73 A (9.014 kW)
Remain Capacity/Energy 524.4 Ah (26.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 88.7 % State Of Health 98.5 %
Run Time 23m to full Report Date 2021-01-12 23:58
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.74 V Cell (MIN/MAX) 3.351 V / 3.366 V (0.015 V)
Current/Power -0.26 A (-13 W) Runtime 28d 8h 9m to empty
Remain Capacity/Energy 174.8 Ah (8.9 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 88.7 % State Of Health 98.5 %
Temperature 19.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-12 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.360 V 3.351 V 3.360 V 3.352 V 3.361 V 3.353 V 3.354 V 3.364 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.361 V 3.353 V 3.363 V 3.355 V 3.364 V 3.356 V 3.365 V 3.366 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -