Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.392 kW
08/27/2025 01:53 (1918 days) Production Consumption NET Usage
Now 0.000 kW 0.392 kW 0.392 kW
Today 0.000 kWh (0.000 kW) 0.586 kWh (0.311 kW) 0.586 kWh (0.311 kW)
  - This Week 71.220 kWh (23.132 kWh/day) 64.520 kWh (20.956 kWh/day) -6.700 kWh (-2.176 kWh/day)
  - This Month 624.323 kWh (23.940 kWh/day) 749.102 kWh (28.724 kWh/day) 124.779 kWh (4.785 kWh/day)
  - This Year 4.382 MWh (18.406 kWh/day) 5.087 MWh (21.366 kWh/day) 0.705 MWh (2.960 kWh/day)
Yesterday 24.392 kWh (1.016 kW) 18.623 kWh (0.776 kW) -5.769 kWh (-0.240 kW)
Last 7 Days 151.821 kWh (21.689 kWh/day) 178.457 kWh (25.494 kWh/day) 26.636 kWh (3.805 kWh/day)
Last 30 Days 719.386 kWh (23.979 kWh/day) 906.653 kWh (30.221 kWh/day) 187.267 kWh (6.242 kWh/day)
Last One Year 6.301 MWh (17.263 kWh/day) 6.986 MWh (19.139 kWh/day) 0.685 MWh (1.876 kWh/day)
Lifetime Since PTO 33.833 MWh (17.639 kW/day) 37.039 MWh (19.310 kW/day) 3.206 MWh (1.671 kW/day)
Lifetime Since Install 33.867 MWh 37.619 MWh 3.752 MWh
Voltage/Current 253.9 V / 0.0 A 254.0 V / 1.5 A 254.0 V / 1.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/14/2020 23:29 (14.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 34.121 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 2.384 2.483 14.569 0.000 kW
2.279 kWh
0.000 kW
13.675 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 2.300 2.388 14.056
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 2.277 2.379 13.992
04 - 202232****** IQ7+ [0] ---- 0.000 0.297 2.305 2.396 14.110
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 2.077 2.179 12.810
06 - 202245****** IQ7+M [0] ---- 0.000 0.296 2.333 2.431 14.257
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.298 2.103 2.109 12.635 0.000 kW
2.119 kWh
0.000 kW
10.594 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 2.125 2.237 13.112
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 2.092 2.152 12.830
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 2.132 2.251 13.175
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 2.143 2.249 13.201
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.291 2.490 2.520 14.731 0.000 kW
2.463 kWh
0.000 kW
9.853 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.293 2.428 2.417 14.287
14 - 202216****** IQ7+ [0] ---- 0.000 0.291 2.491 2.508 14.702
15 - 202245****** IQ7+M [0] ---- 0.000 0.285 2.444 2.460 14.419
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.27 V Current/Power 166.37 A (8.863 kW)
Remain Capacity/Energy 564.3 Ah (28.9 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 97.8 % State Of Health 96.2 %
Run Time 4m to full Report Date 2020-06-14 23:19
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.27 V Cell (MIN/MAX) 3.323 V / 3.333 V (0.010 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 188.1 Ah (9.6 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 97.8 % State Of Health 96.2 %
Temperature 24.0 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-14 23:19
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.325 V 3.325 V 3.326 V 3.327 V 3.328 V 3.328 V 3.328 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.330 V 3.330 V 3.330 V 3.331 V 3.332 V 3.333 V 3.333 V 3.333 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -