Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.092 kW
11/03/2025 20:20 (1986 days) Production Consumption NET Usage
Now 0.000 kW 0.092 kW 0.092 kW
Today 6.646 kWh (0.326 kW) 8.577 kWh (0.421 kW) 1.931 kWh (0.095 kW)
  - This Week 23.817 kWh (12.891 kWh/day) 34.894 kWh (18.886 kWh/day) 11.077 kWh (5.995 kWh/day)
  - This Month 40.755 kWh (14.310 kWh/day) 51.082 kWh (17.936 kWh/day) 10.327 kWh (3.626 kWh/day)
  - This Year 5.619 MWh (18.311 kWh/day) 6.383 MWh (20.803 kWh/day) 0.765 MWh (2.492 kWh/day)
Yesterday 17.171 kWh (0.716 kW) 26.317 kWh (1.097 kW) 9.146 kWh (0.381 kW)
Last 7 Days 86.148 kWh (12.307 kWh/day) 98.955 kWh (14.137 kWh/day) 12.807 kWh (1.830 kWh/day)
Last 30 Days 441.432 kWh (14.715 kWh/day) 484.805 kWh (16.161 kWh/day) 43.373 kWh (1.446 kWh/day)
Last One Year 6.208 MWh (17.008 kWh/day) 7.431 MWh (20.358 kWh/day) 1.223 MWh (3.350 kWh/day)
Lifetime Since PTO 35.070 MWh (17.650 kW/day) 38.336 MWh (19.295 kW/day) 3.267 MWh (1.644 kW/day)
Lifetime Since Install 35.103 MWh 38.916 MWh 3.813 MWh
Voltage/Current 248.8 V / 0.0 A 248.9 V / 0.4 A 248.8 V / 0.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/04/2020 23:14 (13.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.887 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.267 0.645 2.042 11.909 0.000 kW
0.643 kWh
0.000 kW
3.855 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.266 0.637 1.968 11.542
03 - 202224****** IQ7+M [0] ---- 0.000 0.267 0.648 1.990 11.684
04 - 202232****** IQ7+ [0] ---- 0.000 0.267 0.641 2.016 11.777
05 - 202244****** IQ7+M [0] ---- 0.000 0.268 0.642 1.852 10.940
06 - 202245****** IQ7+M [0] ---- 0.000 0.266 0.642 1.974 11.582
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.283 0.597 1.900 10.867 0.000 kW
0.659 kWh
0.000 kW
3.296 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.287 0.694 1.890 11.193
09 - 202217****** IQ7+ [0] ---- 0.000 0.285 0.621 1.893 10.978
10 - 202244****** IQ7+M [0] ---- 0.000 0.287 0.693 1.903 11.287
11 - 202224****** IQ7+M [0] ---- 0.000 0.286 0.691 1.894 11.285
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.192 0.448 1.984 11.339 0.000 kW
0.434 kWh
0.000 kW
1.736 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.159 0.386 1.912 10.908
14 - 202216****** IQ7+ [0] ---- 0.000 0.192 0.456 1.976 11.356
15 - 202245****** IQ7+M [0] ---- 0.000 0.191 0.445 1.945 11.174
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.60 V Current/Power 180.06 A (10.371 kW)
Remain Capacity/Energy 574.5 Ah (29.4 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.5 % State Of Health 96.2 %
Run Time - to full Report Date 2020-08-04 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.60 V Cell (MIN/MAX) 3.586 V / 3.605 V (0.019 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 191.5 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.5 % State Of Health 96.2 %
Temperature 24.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-04 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.596 V 3.600 V 3.599 V 3.602 V 3.599 V 3.601 V 3.586 V 3.602 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.597 V 3.601 V 3.602 V 3.590 V 3.604 V 3.605 V 3.603 V 3.603 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -