Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.034 kW
03/23/2026 19:27 (2126 days) Production Consumption NET Usage
Now 0.316 kW 0.282 kW -0.034 kW
Today 10.785 kWh (0.554 kW) 10.981 kWh (0.564 kW) 0.196 kWh (0.010 kW)
  - This Week 33.533 kWh (18.518 kWh/day) 23.287 kWh (12.860 kWh/day) -10.246 kWh (-5.658 kWh/day)
  - This Month 407.520 kWh (17.865 kWh/day) 360.306 kWh (15.795 kWh/day) -47.214 kWh (-2.070 kWh/day)
  - This Year 1.041 MWh (12.730 kWh/day) 1.460 MWh (17.848 kWh/day) 0.419 MWh (5.118 kWh/day)
Yesterday 22.748 kWh (0.949 kW) 12.306 kWh (0.513 kW) -10.442 kWh (-0.435 kW)
Last 7 Days 155.695 kWh (22.242 kWh/day) 131.578 kWh (18.797 kWh/day) -24.117 kWh (-3.445 kWh/day)
Last 30 Days (02/21/2026) 488.296 kWh (16.277 kWh/day) 459.444 kWh (15.315 kWh/day) -28.852 kWh (-0.962 kWh/day)
Last One Year 6.064 MWh (16.614 kWh/day) 7.893 MWh (21.626 kWh/day) 1.829 MWh (5.011 kWh/day)
Lifetime Since PTO 36.607 MWh (17.212 kW/day) 40.971 MWh (19.264 kW/day) 4.364 MWh (2.052 kW/day)
Lifetime Since Install 36.641 MWh 41.551 MWh 4.910 MWh
Voltage/Current 249.9 V / 1.3 A 249.9 V / 1.1 A 249.9 V / -0.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/20/2020 22:34 (10.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.620 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.233 0.593 0.897 7.434 0.000 kW
0.590 kWh
0.000 kW
3.538 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.230 0.586 0.886 7.295
03 - 202224****** IQ7+M [0] ---- 0.000 0.236 0.594 0.902 7.376
04 - 202232****** IQ7+ [0] ---- 0.000 0.225 0.585 0.892 7.298
05 - 202244****** IQ7+M [0] ---- 0.000 0.237 0.590 0.887 7.340
06 - 202245****** IQ7+M [0] ---- 0.000 0.241 0.591 0.889 7.339
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.280 0.704 0.918 7.989 0.000 kW
0.710 kWh
0.000 kW
3.550 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.280 0.695 0.830 7.386
09 - 202217****** IQ7+ [0] ---- 0.000 0.291 0.715 0.950 8.248
10 - 202244****** IQ7+M [0] ---- 0.000 0.279 0.721 0.955 8.347
11 - 202224****** IQ7+M [0] ---- 0.000 0.276 0.716 0.932 8.205
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.115 0.375 0.742 4.926 0.000 kW
0.383 kWh
0.000 kW
1.531 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.126 0.382 0.743 4.984
14 - 202216****** IQ7+ [0] ---- 0.000 0.128 0.392 0.752 5.088
15 - 202245****** IQ7+M [0] ---- 0.000 0.123 0.383 0.741 5.001
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.02 V Current/Power 175.09 A (9.809 kW)
Remain Capacity/Energy 590.7 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.9 % State Of Health 98.5 %
Run Time - to full Report Date 2020-10-20 23:26
voltag, current for each battery pack voltage, current, and SOC

Voltage 56.02 V Cell (MIN/MAX) 3.495 V / 3.506 V (0.011 V)
Current/Power -0.01 A (0 W) Runtime Stand-by
Remain Capacity/Energy 196.9 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.9 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-10-20 23:26
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.499 V 3.499 V 3.501 V 3.501 V 3.503 V 3.498 V 3.505 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.497 V 3.501 V 3.500 V 3.501 V 3.506 V 3.502 V 3.503 V 3.503 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -