Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.257 kW
05/21/2026 06:22 (2185 days) Production Consumption NET Usage
Now 0.104 kW 0.361 kW 0.257 kW
Today 0.036 kWh (0.006 kW) 3.249 kWh (0.508 kW) 3.213 kWh (0.502 kW)
  - This Week 116.831 kWh (27.384 kWh/day) 132.933 kWh (31.158 kWh/day) 16.102 kWh (3.774 kWh/day)
  - This Month 518.647 kWh (25.592 kWh/day) 332.655 kWh (16.415 kWh/day) -185.992 kWh (-9.178 kWh/day)
  - This Year 2.472 MWh (17.621 kWh/day) 2.392 MWh (17.056 kWh/day) -0.079 MWh (-0.565 kWh/day)
Yesterday 25.684 kWh (1.070 kW) 42.704 kWh (1.779 kW) 17.020 kWh (0.709 kW)
Last 7 Days 191.231 kWh (27.319 kWh/day) 161.891 kWh (23.127 kWh/day) -29.340 kWh (-4.191 kWh/day)
Last 30 Days (04/21/2026) 722.390 kWh (24.080 kWh/day) 414.943 kWh (13.831 kWh/day) -307.447 kWh (-10.248 kWh/day)
Last One Year 6.363 MWh (17.433 kWh/day) 7.797 MWh (21.360 kWh/day) 1.434 MWh (3.928 kWh/day)
Lifetime Since PTO 38.037 MWh (17.406 kW/day) 41.903 MWh (19.175 kW/day) 3.866 MWh (1.769 kW/day)
Lifetime Since Install 38.071 MWh 42.483 MWh 4.412 MWh
Voltage/Current 250.0 V / 0.4 A 250.0 V / 1.4 A 250.0 V / 1.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/24/2020 23:18 (9.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.652 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.219 0.987 0.799 5.181 0.000 kW
0.959 kWh
0.000 kW
5.755 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.218 0.952 0.785 5.076
03 - 202224****** IQ7+M [5] VCOP 0.000 0.217 0.937 0.797 5.089
04 - 202232****** IQ7+ [5] VCOP 0.000 0.217 0.901 0.782 4.931
05 - 202244****** IQ7+M [5] VCOP 0.000 0.223 0.994 0.810 5.202
06 - 202245****** IQ7+M [5] VCOP 0.000 0.221 0.984 0.803 5.163
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.279 1.189 1.034 5.983 0.000 kW
1.216 kWh
0.000 kW
6.081 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.279 1.161 1.049 5.628
09 - 202217****** IQ7+ [5] VCOP 0.000 0.278 1.268 1.059 6.376
10 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.262 1.063 6.342
11 - 202224****** IQ7+M [5] VCOP 0.000 0.279 1.202 1.057 6.055
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.139 0.410 0.289 2.672 0.000 kW
0.454 kWh
0.000 kW
1.816 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.142 0.477 0.348 2.945
14 - 202216****** IQ7+ [5] VCOP 0.000 0.142 0.471 0.344 2.938
15 - 202245****** IQ7+M [5] VCOP 0.000 0.139 0.457 0.336 2.861
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VC-- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 50.96 V Current/Power 159.14 A (8.110 kW)
Remain Capacity/Energy 93.0 Ah (4.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 15.7 % State Of Health 98.5 %
Run Time 3h 7m to full Report Date 2020-11-24 23:20
voltag, current for each battery pack voltage, current, and SOC

Voltage 50.96 V Cell (MIN/MAX) 3.179 V / 3.190 V (0.011 V)
Current/Power -0.50 A (-25 W) Runtime 2d 14h 0m to empty
Remain Capacity/Energy 31.0 Ah (1.6 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 15.7 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-24 23:20
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.180 V 3.179 V 3.182 V 3.181 V 3.184 V 3.183 V 3.185 V 3.186 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.185 V 3.185 V 3.187 V 3.187 V 3.189 V 3.188 V 3.189 V 3.190 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -