Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.502 kW
07/03/2026 15:36 (2228 days) Production Consumption NET Usage
Now 3.881 kW 2.379 kW -1.502 kW
Today 25.600 kWh (1.638 kW) 25.713 kWh (1.645 kW) 0.113 kWh (0.007 kW)
  - This Week 168.474 kWh (29.816 kWh/day) 185.851 kWh (32.892 kWh/day) 17.377 kWh (3.075 kWh/day)
  - This Month 86.873 kWh (32.770 kWh/day) 111.711 kWh (42.139 kWh/day) 24.838 kWh (9.369 kWh/day)
  - This Year 3.697 MWh (20.129 kWh/day) 3.398 MWh (18.505 kWh/day) -0.298 MWh (-1.624 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 183.744 kWh (26.249 kWh/day) 214.275 kWh (30.611 kWh/day) 30.531 kWh (4.362 kWh/day)
Last 30 Days (06/03/2026) 859.335 kWh (28.645 kWh/day) 800.891 kWh (26.696 kWh/day) -58.444 kWh (-1.948 kWh/day)
Last One Year 6.719 MWh (18.409 kWh/day) 7.754 MWh (21.245 kWh/day) 1.035 MWh (2.835 kWh/day)
Lifetime Since PTO 39.262 MWh (17.617 kW/day) 42.909 MWh (19.253 kW/day) 3.647 MWh (1.636 kW/day)
Lifetime Since Install 39.296 MWh 43.489 MWh 4.193 MWh
Voltage/Current 247.1 V / 15.7 A 247.1 V / 9.6 A 247.1 V / -6.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/12/2025 23:47 (17.6 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.507 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.212 1.024 0.983 4.947 0.000 kW
1.006 kWh
0.000 kW
6.038 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.203 0.980 0.941 4.711
03 - 202224****** IQ7+M [5] VCOP 0.000 0.210 1.019 0.994 4.958
04 - 202232****** IQ7+ [5] VCOP 0.000 0.210 1.031 1.004 4.990
05 - 202244****** IQ7+M [5] VCOP 0.000 0.204 0.986 0.933 4.699
06 - 202245****** IQ7+M [5] VCOP 0.000 0.207 0.997 0.939 4.784
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.270 1.038 1.067 4.849 0.000 kW
1.218 kWh
0.000 kW
6.089 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.277 1.226 1.171 5.554
09 - 202217****** IQ7+ [5] VCOP 0.000 0.277 1.334 1.214 5.863
10 - 202244****** IQ7+M [5] VCOP 0.000 0.274 1.296 1.209 5.795
11 - 202224****** IQ7+M [5] VCOP 0.000 0.277 1.194 1.166 5.443
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.072 0.297 0.438 2.500 0.000 kW
0.366 kWh
0.000 kW
1.462 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.085 0.380 0.509 2.784
14 - 202216****** IQ7+ [5] VCOP 0.000 0.089 0.399 0.527 2.906
15 - 202245****** IQ7+M [5] VCOP 0.000 0.087 0.386 0.528 2.885
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.639 kWh
0.000 kW
1.918 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.230 1.918 4.792 21.541
Panel Layout Each Group Production

Charger History
Voltage PV 0.37 V Voltage Charge 52.44 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.8 °C / 23.7 °C Flags 00/00/00 Energy Today 5.378 kWh @ 2025-12-12 23:56
voltage in/out power and energy

Battery History
Voltage 52.62 V Current/Power -1.50 A (-78 W)
Remain Capacity/Energy 185.1 Ah (9.5 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 31.2 % State Of Health 98.9 %
Run Time 5d 3h 24m to empty Report Date 2025-12-12 23:56
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.