Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.151 kW
05/21/2026 07:18 (2185 days) Production Consumption NET Usage
Now 0.214 kW 0.365 kW 0.151 kW
Today 0.188 kWh (0.026 kW) 3.579 kWh (0.488 kW) 3.391 kWh (0.462 kW)
  - This Week 116.983 kWh (27.172 kWh/day) 133.263 kWh (30.954 kWh/day) 16.280 kWh (3.781 kWh/day)
  - This Month 518.799 kWh (25.551 kWh/day) 332.985 kWh (16.399 kWh/day) -185.814 kWh (-9.151 kWh/day)
  - This Year 2.472 MWh (17.618 kWh/day) 2.393 MWh (17.054 kWh/day) -0.079 MWh (-0.564 kWh/day)
Yesterday 25.684 kWh (1.070 kW) 42.704 kWh (1.779 kW) 17.020 kWh (0.709 kW)
Last 7 Days 190.959 kWh (27.280 kWh/day) 161.911 kWh (23.130 kWh/day) -29.048 kWh (-4.150 kWh/day)
Last 30 Days (04/21/2026) 722.356 kWh (24.079 kWh/day) 415.105 kWh (13.837 kWh/day) -307.251 kWh (-10.242 kWh/day)
Last One Year 6.363 MWh (17.433 kWh/day) 7.796 MWh (21.359 kWh/day) 1.433 MWh (3.926 kWh/day)
Lifetime Since PTO 38.038 MWh (17.406 kW/day) 41.903 MWh (19.175 kW/day) 3.866 MWh (1.769 kW/day)
Lifetime Since Install 38.071 MWh 42.483 MWh 4.412 MWh
Voltage/Current 249.1 V / 0.9 A 249.1 V / 1.5 A 249.1 V / 0.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/28/2020 23:24 (9.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.347 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.122 0.234 0.573 2.988 0.000 kW
0.231 kWh
0.000 kW
1.387 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.122 0.230 0.566 2.947
03 - 202224****** IQ7+M [5] VCOP 0.000 0.122 0.236 0.577 3.007
04 - 202232****** IQ7+ [5] VCOP 0.000 0.120 0.231 0.567 2.961
05 - 202244****** IQ7+M [5] VCOP 0.000 0.121 0.227 0.563 2.933
06 - 202245****** IQ7+M [5] VCOP 0.000 0.121 0.229 0.566 2.941
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.122 0.212 0.593 2.982 0.000 kW
0.214 kWh
0.000 kW
1.069 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.122 0.213 0.591 2.914
09 - 202217****** IQ7+ [5] VCOP 0.000 0.121 0.214 0.597 3.048
10 - 202244****** IQ7+M [5] VCOP 0.000 0.123 0.216 0.600 3.066
11 - 202224****** IQ7+M [5] VCOP 0.000 0.121 0.214 0.594 3.021
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.105 0.221 0.437 2.460 0.000 kW
0.223 kWh
0.000 kW
0.891 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.105 0.222 0.444 2.493
14 - 202216****** IQ7+ [5] VCOP 0.000 0.106 0.226 0.449 2.530
15 - 202245****** IQ7+M [5] VCOP 0.000 0.106 0.222 0.441 2.482
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.01 V Current/Power 178.04 A (10.150 kW)
Remain Capacity/Energy 591.0 Ah (30.3 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 100.0 % State Of Health 98.5 %
Run Time - to full Report Date 2020-10-28 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.01 V Cell (MIN/MAX) 3.552 V / 3.568 V (0.016 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 197.0 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 100.0 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-10-28 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.559 V 3.561 V 3.560 V 3.563 V 3.552 V 3.554 V 3.568 V 3.563 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.558 V 3.563 V 3.567 V 3.567 V 3.566 V 3.568 V 3.567 V 3.567 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -