Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.727 kW
07/03/2026 13:46 (2228 days) Production Consumption NET Usage
Now 4.189 kW 2.462 kW -1.727 kW
Today 19.288 kWh (1.399 kW) 21.923 kWh (1.590 kW) 2.635 kWh (0.191 kW)
  - This Week 162.162 kWh (29.094 kWh/day) 182.061 kWh (32.664 kWh/day) 19.899 kWh (3.570 kWh/day)
  - This Month 80.561 kWh (31.293 kWh/day) 107.921 kWh (41.921 kWh/day) 27.360 kWh (10.628 kWh/day)
  - This Year 3.690 MWh (20.103 kWh/day) 3.395 MWh (18.492 kWh/day) -0.296 MWh (-1.611 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 183.234 kWh (26.176 kWh/day) 212.025 kWh (30.289 kWh/day) 28.791 kWh (4.113 kWh/day)
Last 30 Days (06/03/2026) 860.670 kWh (28.689 kWh/day) 799.285 kWh (26.643 kWh/day) -61.385 kWh (-2.046 kWh/day)
Last One Year 6.718 MWh (18.407 kWh/day) 7.753 MWh (21.241 kWh/day) 1.035 MWh (2.835 kWh/day)
Lifetime Since PTO 39.256 MWh (17.615 kW/day) 42.905 MWh (19.252 kW/day) 3.649 MWh (1.638 kW/day)
Lifetime Since Install 39.290 MWh 43.485 MWh 4.195 MWh
Voltage/Current 247.5 V / 16.9 A 247.3 V / 10.0 A 247.4 V / -7.0 A
Meter

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 12/11/2025 23:57 (14.9 hours) Number of Devices 18 set
Current Power 0.230 kW (0.013 kW/panel) Today Energy 18.413 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.219 0.983 0.493 4.525 0.000 kW
0.965 kWh
0.000 kW
5.793 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.211 0.941 0.465 4.308
03 - 202224****** IQ7+M [5] VCOP 0.000 0.218 0.994 0.491 4.525
04 - 202232****** IQ7+ [5] VCOP 0.000 0.217 1.004 0.492 4.547
05 - 202244****** IQ7+M [5] VCOP 0.000 0.212 0.933 0.461 4.300
06 - 202245****** IQ7+M [5] VCOP 0.000 0.214 0.939 0.475 4.390
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.275 1.067 0.464 4.458 0.000 kW
1.165 kWh
0.000 kW
5.826 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.282 1.171 0.506 5.074
09 - 202217****** IQ7+ [5] VCOP 0.000 0.284 1.214 0.520 5.353
10 - 202244****** IQ7+M [5] VCOP 0.000 0.282 1.209 0.521 5.277
11 - 202224****** IQ7+M [5] VCOP 0.000 0.289 1.166 0.495 4.971
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.073 0.438 0.350 2.310 0.000 kW
0.500 kWh
0.000 kW
2.002 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.089 0.509 0.371 2.554
14 - 202216****** IQ7+ [5] VCOP 0.000 0.092 0.527 0.386 2.673
15 - 202245****** IQ7+M [5] VCOP 0.000 0.091 0.528 0.388 2.648
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.077 kW
1.597 kWh
0.230 kW
4.792 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.230 0.230 4.792 3.676 16.749
Panel Layout Each Group Production

Charger History
Voltage PV 0.40 V Voltage Charge 51.90 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.6 °C / 25.3 °C Flags 00/00/00 Energy Today 4.561 kWh @ 2025-12-11 23:58
voltage in/out power and energy

Battery History
Voltage 52.16 V Current/Power -6.44 A (-0.336 kW)
Remain Capacity/Energy 179.4 Ah (9.2 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 30.3 % State Of Health 98.9 %
Run Time 1d 3h 51m to empty Report Date 2025-12-11 23:56
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.