Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.145 kW
07/06/2026 12:36 (2231 days) Production Consumption NET Usage
Now 0.324 kW 0.469 kW 0.145 kW
Today 1.617 kWh (0.128 kW) 7.517 kWh (0.596 kW) 5.900 kWh (0.467 kW)
  - This Week 18.038 kWh (11.814 kWh/day) 38.455 kWh (25.187 kWh/day) 20.417 kWh (13.372 kWh/day)
  - This Month 145.802 kWh (26.383 kWh/day) 209.918 kWh (37.984 kWh/day) 64.116 kWh (11.602 kWh/day)
  - This Year 3.756 MWh (20.135 kWh/day) 3.497 MWh (18.746 kWh/day) -0.259 MWh (-1.388 kWh/day)
Yesterday 16.421 kWh (0.684 kW) 30.938 kWh (1.288 kW) 14.517 kWh (0.604 kW)
Last 7 Days 188.234 kWh (26.891 kWh/day) 247.246 kWh (35.321 kWh/day) 59.012 kWh (8.430 kWh/day)
Last 30 Days (06/06/2026) 815.349 kWh (27.178 kWh/day) 834.513 kWh (27.817 kWh/day) 19.164 kWh (0.639 kWh/day)
Last One Year 6.699 MWh (18.353 kWh/day) 7.750 MWh (21.232 kWh/day) 1.051 MWh (2.879 kWh/day)
Lifetime Since PTO 39.321 MWh (17.621 kW/day) 43.007 MWh (19.273 kW/day) 3.686 MWh (1.652 kW/day)
Lifetime Since Install 39.355 MWh 43.587 MWh 4.232 MWh
Voltage/Current 249.9 V / 1.3 A 249.7 V / 1.9 A 249.8 V / 0.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/21/2020 23:04 (11.9 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.971 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.269 1.826 1.820 10.893 0.000 kW
1.808 kWh
0.000 kW
10.850 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.266 1.813 1.810 10.793
03 - 202224****** IQ7+M [5] VCOP 0.000 0.270 1.841 1.839 10.961
04 - 202232****** IQ7+ [5] VCOP 0.000 0.268 1.832 1.834 10.892
05 - 202244****** IQ7+M [5] VCOP 0.000 0.267 1.776 1.760 10.612
06 - 202245****** IQ7+M [5] VCOP 0.000 0.263 1.761 1.744 10.599
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.921 1.890 11.150 0.000 kW
1.906 kWh
0.000 kW
9.529 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.800 1.799 10.715
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.928 1.895 11.210
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.946 1.920 11.319
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.935 1.912 11.245
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.204 1.409 1.414 8.843 0.000 kW
1.398 kWh
0.000 kW
5.592 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.205 1.377 1.371 8.694
14 - 202216****** IQ7+ [5] VCOP 0.000 0.206 1.415 1.423 8.895
15 - 202245****** IQ7+M [5] VCOP 0.000 0.201 1.391 1.400 8.755
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [4] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.