Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.461 kW
07/06/2026 14:28 (2231 days) Production Consumption NET Usage
Now 0.270 kW 2.731 kW 2.461 kW
Today 2.374 kWh (0.164 kW) 8.850 kWh (0.611 kW) 6.476 kWh (0.447 kW)
  - This Week 18.795 kWh (11.715 kWh/day) 39.788 kWh (24.801 kWh/day) 20.993 kWh (13.085 kWh/day)
  - This Month 146.559 kWh (26.153 kWh/day) 211.251 kWh (37.697 kWh/day) 64.692 kWh (11.544 kWh/day)
  - This Year 3.756 MWh (20.130 kWh/day) 3.498 MWh (18.746 kWh/day) -0.258 MWh (-1.385 kWh/day)
Yesterday 16.421 kWh (0.684 kW) 30.938 kWh (1.288 kW) 14.517 kWh (0.604 kW)
Last 7 Days 183.449 kWh (26.207 kWh/day) 246.923 kWh (35.275 kWh/day) 63.474 kWh (9.068 kWh/day)
Last 30 Days (06/06/2026) 810.072 kWh (27.002 kWh/day) 833.646 kWh (27.788 kWh/day) 23.574 kWh (0.786 kWh/day)
Last One Year 6.693 MWh (18.336 kWh/day) 7.747 MWh (21.224 kWh/day) 1.054 MWh (2.888 kWh/day)
Lifetime Since PTO 39.322 MWh (17.621 kW/day) 43.009 MWh (19.273 kW/day) 3.687 MWh (1.652 kW/day)
Lifetime Since Install 39.356 MWh 43.589 MWh 4.233 MWh
Voltage/Current 248.8 V / 1.1 A 248.8 V / 11.0 A 248.8 V / 9.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/07/2020 21:00 (14.4 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.896 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.294 1.093 1.512 12.359 0.000 kW
1.046 kWh
0.000 kW
6.275 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.037 1.445 12.010
03 - 202224****** IQ7+M [5] VCOP 0.000 0.292 1.045 1.425 12.002
04 - 202232****** IQ7+ [5] VCOP 0.000 0.294 1.039 1.449 12.044
05 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.005 1.246 11.143
06 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.056 1.467 12.087
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.288 0.957 1.231 10.881 0.000 kW
0.965 kWh
0.000 kW
4.826 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.285 0.956 1.262 11.216
09 - 202217****** IQ7+ [5] VCOP 0.000 0.284 0.970 1.248 11.071
10 - 202244****** IQ7+M [5] VCOP 0.000 0.287 0.976 1.268 11.287
11 - 202224****** IQ7+M [5] VCOP 0.000 0.283 0.968 1.260 11.247
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.291 1.192 1.660 12.125 0.000 kW
1.199 kWh
0.000 kW
4.794 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.294 1.197 1.652 11.883
14 - 202216****** IQ7+ [5] VCOP 0.000 0.291 1.209 1.667 12.173
15 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.196 1.644 11.963
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.61 V Current/Power 179.75 A (10.356 kW)
Remain Capacity/Energy 576.9 Ah (29.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.9 % State Of Health 96.2 %
Run Time - to full Report Date 2020-07-07 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.