Date Offset  [+30][+10][+05][+01][-01][-05][-10]

Importing from grid by 0.515 kW
10/20/2025 19:44 (1972 days) Production Consumption NET Usage
Now 0.000 kW 0.515 kW 0.515 kW
Today 9.694 kWh (0.491 kW) 11.621 kWh (0.589 kW) 1.927 kWh (0.098 kW)
  - This Week 27.369 kWh (15.017 kWh/day) 30.083 kWh (16.506 kWh/day) 2.714 kWh (1.489 kWh/day)
  - This Month 338.459 kWh (17.075 kWh/day) 335.873 kWh (16.944 kWh/day) -2.586 kWh (-0.130 kWh/day)
  - This Year 5.438 MWh (18.570 kWh/day) 6.191 MWh (21.142 kWh/day) 0.753 MWh (2.572 kWh/day)
Yesterday 17.675 kWh (0.736 kW) 18.462 kWh (0.769 kW) 0.787 kWh (0.033 kW)
Last 7 Days 108.364 kWh (15.480 kWh/day) 101.909 kWh (14.558 kWh/day) -6.455 kWh (-0.922 kWh/day)
Last 30 Days 513.806 kWh (17.127 kWh/day) 564.177 kWh (18.806 kWh/day) 50.371 kWh (1.679 kWh/day)
Last One Year 6.274 MWh (17.189 kWh/day) 7.416 MWh (20.318 kWh/day) 1.142 MWh (3.129 kWh/day)
Lifetime Since PTO 34.889 MWh (17.685 kW/day) 38.143 MWh (19.334 kW/day) 3.254 MWh (1.650 kW/day)
Lifetime Since Install 34.922 MWh 38.723 MWh 3.800 MWh
Voltage/Current 252.2 V / 0.0 A 252.3 V / 2.0 A 252.3 V / 2.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/27/2025 23:54 (2.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.266 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.117 0.458 1.579 8.134 0.000 kW
0.442 kWh
0.000 kW
2.655 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.111 0.435 1.506 7.776
03 - 202224****** IQ7+M [0] ---- 0.000 0.110 0.436 1.560 8.075
04 - 202232****** IQ7+ [0] ---- 0.000 0.116 0.455 1.565 8.132
05 - 202244****** IQ7+M [0] ---- 0.000 0.108 0.424 1.488 7.633
06 - 202245****** IQ7+M [0] ---- 0.000 0.114 0.446 1.525 7.833
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.127 0.493 1.537 7.928 0.000 kW
0.484 kWh
0.000 kW
2.422 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.125 0.485 1.650 8.348
09 - 202217****** IQ7+ [0] ---- 0.000 0.129 0.497 1.649 8.366
10 - 202244****** IQ7+M [0] ---- 0.000 0.128 0.496 1.649 8.367
11 - 202224****** IQ7+M [0] ---- 0.000 0.114 0.452 1.668 8.460
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.071 0.292 1.065 6.101 0.000 kW
0.297 kWh
0.000 kW
1.189 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.070 0.291 1.089 6.283
14 - 202216****** IQ7+ [0] ---- 0.000 0.076 0.313 1.124 6.506
15 - 202245****** IQ7+M [0] ---- 0.000 0.075 0.294 1.120 6.513
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 23.707 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 1.19 V Voltage Charge 52.58 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 29.4 °C / 27.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-09-27 23:55
voltage in/out power and energy

Battery History
Voltage 52.80 V Current/Power -1.80 A (-95 W)
Remain Capacity/Energy 318.6 Ah (16.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 53.7 % State Of Health 98.9 %
Run Time 7d 9h 0m to empty Report Date 2025-09-27 23:56
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.