Date Offset  [+30][+10][+05][+01][-01][-05][-10]

Importing from grid by 0.120 kW
07/03/2026 06:46 (2228 days) Production Consumption NET Usage
Now 0.588 kW 0.708 kW 0.120 kW
Today 1.738 kWh (0.256 kW) 10.415 kWh (1.533 kW) 8.677 kWh (1.277 kW)
  - This Week 144.612 kWh (27.377 kWh/day) 170.553 kWh (32.288 kWh/day) 25.941 kWh (4.911 kWh/day)
  - This Month 63.011 kWh (27.602 kWh/day) 96.413 kWh (42.235 kWh/day) 33.402 kWh (14.632 kWh/day)
  - This Year 3.673 MWh (20.039 kWh/day) 3.383 MWh (18.459 kWh/day) -0.290 MWh (-1.580 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 173.402 kWh (24.772 kWh/day) 204.547 kWh (29.221 kWh/day) 31.145 kWh (4.449 kWh/day)
Last 30 Days (06/03/2026) 862.927 kWh (28.764 kWh/day) 794.720 kWh (26.491 kWh/day) -68.207 kWh (-2.274 kWh/day)
Last One Year 6.716 MWh (18.400 kWh/day) 7.750 MWh (21.233 kWh/day) 1.034 MWh (2.833 kWh/day)
Lifetime Since PTO 39.239 MWh (17.609 kW/day) 42.894 MWh (19.250 kW/day) 3.655 MWh (1.640 kW/day)
Lifetime Since Install 39.272 MWh 43.474 MWh 4.201 MWh
Voltage/Current 250.7 V / 2.3 A 250.6 V / 2.8 A 250.7 V / 0.5 A
Meter

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 06/08/2026 23:56 (23.9 hours) Number of Devices 18 set
Current Power 0.321 kW (0.018 kW/panel) Today Energy 40.983 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.263 2.120 14.930 0.000 kW
2.133 kWh
0.000 kW
12.796 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.286 2.104 1.969 13.871
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.142 1.991 14.064
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.196 2.021 14.301
05 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.904 1.774 12.593
06 - 202245****** IQ7+M [5] VCOP 0.000 0.294 2.188 2.050 14.394
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.287 2.003 1.879 13.191 0.000 kW
2.029 kWh
0.000 kW
10.147 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.293 2.047 1.813 13.059
09 - 202217****** IQ7+ [5] VCOP 0.000 0.293 2.028 1.865 13.221
10 - 202244****** IQ7+M [5] VCOP 0.000 0.290 2.017 1.908 13.387
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.051 1.942 13.644
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.272 2.273 2.104 14.805 0.000 kW
2.313 kWh
0.000 kW
9.250 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.278 2.270 2.076 14.708
14 - 202216****** IQ7+ [5] VCOP 0.000 0.280 2.344 2.152 15.193
15 - 202245****** IQ7+M [5] VCOP 0.000 0.282 2.363 2.154 15.228
wind 16 - 202320****** IQ7XS [0] ---- 0.321 0.322 7.690 7.676 50.656 0.107 kW
2.930 kWh
0.321 kW
8.789 kWh
17 - 122344****** IQ7AS [4] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.150 1.100 0.916 6.638
Panel Layout Each Group Production

Charger History
Voltage PV 0.24 V Voltage Charge 52.81 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.3 °C / 27.1 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2026-06-08 23:56
voltage in/out power and energy

Battery History
Voltage 53.10 V Current/Power -7.85 A (-0.417 kW)
Remain Capacity/Energy 403.3 Ah (20.6 kWh) Full Capacity/Energy 548.1 Ah (28.1 kWh)
State Of Charge 73.6 % State Of Health 91.4 %
Run Time 2d 3h 22m to empty Report Date 2026-06-09 00:00
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.