Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.259 kW
07/04/2025 07:46 (1864 days) Production Consumption NET Usage
Now 0.718 kW 0.459 kW -0.259 kW
Today 0.725 kWh (0.093 kW) 2.995 kWh (0.385 kW) 2.270 kWh (0.292 kW)
  - This Week 123.824 kWh (23.257 kWh/day) 159.368 kWh (29.933 kWh/day) 35.544 kWh (6.676 kWh/day)
  - This Month 66.538 kWh (20.011 kWh/day) 91.686 kWh (27.575 kWh/day) 25.148 kWh (7.563 kWh/day)
  - This Year 3.096 MWh (16.798 kWh/day) 3.219 MWh (17.463 kWh/day) 0.123 MWh (0.666 kWh/day)
Yesterday 24.042 kWh (1.001 kW) 27.565 kWh (1.148 kW) 3.523 kWh (0.147 kW)
Last 7 Days 156.185 kWh (22.312 kWh/day) 227.613 kWh (32.515 kWh/day) 71.428 kWh (10.204 kWh/day)
Last 30 Days 613.088 kWh (20.436 kWh/day) 820.402 kWh (27.346 kWh/day) 207.314 kWh (6.910 kWh/day)
Last One Year 6.311 MWh (17.291 kWh/day) 6.385 MWh (17.493 kWh/day) 0.074 MWh (0.202 kWh/day)
Lifetime Since PTO 32.547 MWh (17.458 kW/day) 35.171 MWh (18.865 kW/day) 2.624 MWh (1.407 kW/day)
Lifetime Since Install 32.581 MWh 35.751 MWh 3.170 MWh
Voltage/Current 249.2 V / 2.9 A 249.0 V / 1.8 A 249.1 V / -1.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/12/2024 23:34 (11.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.100 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.251 1.618 2.477 10.404 0.000 kW
1.552 kWh
0.000 kW
9.311 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.238 1.525 2.358 9.897
03 - 202224****** IQ7+M [5] VCOP 0.000 0.247 1.547 2.417 10.200
04 - 202232****** IQ7+ [5] VCOP 0.000 0.248 1.534 2.411 10.232
05 - 202244****** IQ7+M [5] VCOP 0.000 0.239 1.528 2.373 9.825
06 - 202245****** IQ7+M [5] VCOP 0.000 0.243 1.558 2.412 9.996
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.287 1.635 2.769 10.350 0.000 kW
1.782 kWh
0.000 kW
8.911 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.287 1.781 2.791 11.194
09 - 202217****** IQ7+ [5] VCOP 0.000 0.288 1.821 2.765 11.295
10 - 202244****** IQ7+M [5] VCOP 0.000 0.283 1.828 2.753 11.299
11 - 202224****** IQ7+M [5] VCOP 0.000 0.291 1.847 2.803 11.452
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.154 0.894 1.420 6.495 0.000 kW
0.969 kWh
0.000 kW
3.878 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.159 0.973 1.511 6.900
14 - 202216****** IQ7+ [5] VCOP 0.000 0.162 1.011 1.553 7.151
15 - 202245****** IQ7+M [5] VCOP 0.000 0.161 1.000 1.536 7.088
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 5.283 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 0.35 V Voltage Charge 52.97 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.8 °C / 25.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-10-12 23:57
voltage in/out power and energy

Battery History
Voltage 53.19 V Current/Power -1.47 A (-78 W)
Remain Capacity/Energy 521.7 Ah (26.7 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 88.0 % State Of Health 98.9 %
Run Time 14d 18h 53m to empty Report Date 2024-10-12 23:57
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.19 V Cell (MIN/MAX) 3.319 V / 3.328 V (0.009 V)
Current/Power -0.49 A (-26 W) Runtime 14d 18h 10m to empty
Remain Capacity/Energy 173.9 Ah (8.9 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 88.0 % State Of Health 98.8 %
Temperature 22.5 °C Cycle 170
MOSFET CFET = ON, DFET = ON Reported 2024-10-12 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.319 V 3.320 V 3.320 V 3.321 V 3.322 V 3.322 V 3.323 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.324 V 3.325 V 3.326 V 3.327 V 3.327 V 3.328 V 3.328 V
pack voltage and current cell voltages