Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.033 kW
05/18/2025 06:51 (1817 days) Production Consumption NET Usage
Now 0.401 kW 0.368 kW -0.033 kW
Today 0.177 kWh (0.026 kW) 2.571 kWh (0.373 kW) 2.394 kWh (0.348 kW)
  - This Week 0.177 kWh (0.617 kWh/day) 2.571 kWh (8.961 kWh/day) 2.394 kWh (8.344 kWh/day)
  - This Month 316.812 kWh (18.328 kWh/day) 251.721 kWh (14.562 kWh/day) -65.091 kWh (-3.766 kWh/day)
  - This Year 2.140 MWh (15.589 kWh/day) 2.060 MWh (15.008 kWh/day) -0.080 MWh (-0.580 kWh/day)
Yesterday 26.376 kWh (1.099 kW) 22.695 kWh (0.946 kW) -3.681 kWh (-0.153 kW)
Last 7 Days 134.879 kWh (19.270 kWh/day) 110.358 kWh (15.767 kWh/day) -24.521 kWh (-3.503 kWh/day)
Last 30 Days 642.393 kWh (21.414 kWh/day) 468.858 kWh (15.629 kWh/day) -173.535 kWh (-5.785 kWh/day)
Last One Year 6.688 MWh (18.322 kWh/day) 6.275 MWh (17.193 kWh/day) -0.412 MWh (-1.129 kWh/day)
Lifetime Since PTO 31.591 MWh (17.384 kW/day) 34.012 MWh (18.716 kW/day) 2.421 MWh (1.332 kW/day)
Lifetime Since Install 31.625 MWh 34.592 MWh 2.967 MWh
Voltage/Current 252.3 V / 1.6 A 252.3 V / 1.5 A 252.3 V / -0.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/11/2024 23:09 (19.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.740 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.042 0.585 8.563 0.000 kW
1.939 kWh
0.000 kW
11.637 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.913 0.552 8.031
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.970 0.583 8.343
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.017 0.579 8.461
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.747 0.538 7.550
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.949 0.559 8.162
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.847 0.527 7.892 0.000 kW
1.857 kWh
0.000 kW
9.287 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.862 0.533 7.854
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.852 0.531 7.820
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.853 0.529 7.886
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.874 0.534 8.018
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.293 1.892 0.524 7.695 0.000 kW
1.967 kWh
0.000 kW
7.867 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.295 1.939 0.555 7.873
14 - 202216****** IQ7+ [5] VCOP 0.000 0.296 2.018 0.594 8.302
15 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.018 0.592 8.285
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.230 1.949 5.497 38.465 0.000 kW
1.949 kWh
0.000 kW
1.949 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.80 A (-95 W)
Remain Capacity/Energy 507.0 Ah (26.0 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 85.5 % State Of Health 98.9 %
Run Time 11d 17h 40m to empty Report Date 2024-05-11 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.21 V Cell (MIN/MAX) 3.320 V / 3.329 V (0.009 V)
Current/Power -0.58 A (-30 W) Runtime 12d 3h 22m to empty
Remain Capacity/Energy 169.0 Ah (8.7 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 85.5 % State Of Health 98.8 %
Temperature 21.0 °C Cycle 146
MOSFET CFET = ON, DFET = ON Reported 2024-05-11 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.320 V 3.322 V 3.321 V 3.323 V 3.322 V 3.324 V 3.325 V 3.324 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.327 V 3.326 V 3.328 V 3.328 V 3.329 V 3.329 V 3.328 V
pack voltage and current cell voltages
pack temperature