Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.301 kW
03/20/2026 23:38 (2123 days) Production Consumption NET Usage
Now 0.000 kW 0.301 kW 0.301 kW
Today 19.934 kWh (0.843 kW) 12.912 kWh (0.546 kW) -7.022 kWh (-0.297 kW)
  - This Week 113.737 kWh (19.003 kWh/day) 118.183 kWh (19.746 kWh/day) 4.446 kWh (0.743 kWh/day)
  - This Month 348.458 kWh (17.436 kWh/day) 322.210 kWh (16.122 kWh/day) -26.248 kWh (-1.313 kWh/day)
  - This Year 0.982 MWh (12.437 kWh/day) 1.422 MWh (18.004 kWh/day) 0.440 MWh (5.566 kWh/day)
Yesterday 13.403 kWh (0.558 kW) 14.863 kWh (0.619 kW) 1.460 kWh (0.061 kW)
Last 7 Days 148.023 kWh (21.146 kWh/day) 133.413 kWh (19.059 kWh/day) -14.610 kWh (-2.087 kWh/day)
Last 30 Days (02/18/2026) 451.578 kWh (15.053 kWh/day) 499.588 kWh (16.653 kWh/day) 48.010 kWh (1.600 kWh/day)
Last One Year 6.083 MWh (16.665 kWh/day) 7.889 MWh (21.614 kWh/day) 1.806 MWh (4.949 kWh/day)
Lifetime Since PTO 36.548 MWh (17.207 kW/day) 40.933 MWh (19.272 kW/day) 4.385 MWh (2.064 kW/day)
Lifetime Since Install 36.582 MWh 41.513 MWh 4.931 MWh
Voltage/Current 251.1 V / 0.0 A 251.0 V / 1.2 A 251.1 V / 1.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/22/2025 23:53 (10.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.059 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.268 1.681 1.738 7.496 0.000 kW
1.634 kWh
0.000 kW
9.806 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.257 1.598 1.652 7.081
03 - 202224****** IQ7+M [0] ---- 0.000 0.265 1.655 1.705 7.357
04 - 202232****** IQ7+ [0] ---- 0.000 0.267 1.654 1.699 7.333
05 - 202244****** IQ7+M [0] ---- 0.000 0.257 1.593 1.653 7.063
06 - 202245****** IQ7+M [0] ---- 0.000 0.259 1.625 1.686 7.239
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 1.674 1.761 7.252 0.000 kW
1.841 kWh
0.000 kW
9.206 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.830 1.915 7.923
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 1.911 2.001 8.321
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.901 2.003 8.284
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.889 1.987 8.192
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.167 0.936 0.931 4.606 0.000 kW
1.012 kWh
0.000 kW
4.047 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.170 1.019 1.016 4.958
14 - 202216****** IQ7+ [0] ---- 0.000 0.172 1.049 1.046 5.127
15 - 202245****** IQ7+M [0] ---- 0.000 0.171 1.042 1.038 5.109
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 0.31 V Voltage Charge 52.85 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.1 °C / 24.7 °C Flags 00/00/00 Energy Today 10.252 kWh @ 2025-02-22 23:57
voltage in/out power and energy

Battery History
Voltage 53.12 V Current/Power -6.37 A (-0.338 kW)
Remain Capacity/Energy 559.5 Ah (28.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 94.3 % State Of Health 98.9 %
Run Time 3d 15h 50m to empty Report Date 2025-02-22 23:55
voltag, current for each battery pack voltage, current, and SOC