Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.442 kW
02/01/2026 11:07 (2076 days) Production Consumption NET Usage
Now 2.655 kW 0.213 kW -2.442 kW
Today 7.049 kWh (0.633 kW) 7.874 kWh (0.707 kW) 0.825 kWh (0.074 kW)
  - This Week 7.049 kWh (15.187 kWh/day) 7.874 kWh (16.964 kWh/day) 0.825 kWh (1.777 kWh/day)
  - This Month 7.049 kWh (15.187 kWh/day) 7.874 kWh (16.964 kWh/day) 0.825 kWh (1.777 kWh/day)
  - This Year 0.252 MWh (8.024 kWh/day) 0.591 MWh (18.785 kWh/day) 0.339 MWh (10.761 kWh/day)
Yesterday 17.942 kWh (0.748 kW) 16.650 kWh (0.694 kW) -1.292 kWh (-0.054 kW)
Last 7 Days 46.574 kWh (7.126 kWh/day) 101.584 kWh (15.543 kWh/day) 55.010 kWh (8.417 kWh/day)
Last 30 Days 232.892 kWh (7.885 kWh/day) 567.139 kWh (19.201 kWh/day) 334.247 kWh (11.316 kWh/day)
Last One Year 6.091 MWh (16.709 kWh/day) 7.498 MWh (20.569 kWh/day) 1.407 MWh (3.860 kWh/day)
Lifetime Since PTO 35.818 MWh (17.249 kW/day) 40.103 MWh (19.313 kW/day) 4.284 MWh (2.063 kW/day)
Lifetime Since Install 35.852 MWh 40.682 MWh 4.830 MWh
Voltage/Current 251.6 V / 10.6 A 251.7 V / 0.8 A 251.7 V / -9.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/15/2025 23:39 (9.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.330 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.181 0.422 0.010 4.497 0.000 kW
0.378 kWh
0.000 kW
2.266 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.159 0.424 0.011 4.282
03 - 202224****** IQ7+M [5] VCOP 0.000 0.151 0.329 0.007 4.498
04 - 202232****** IQ7+ [5] VCOP 0.000 0.176 0.417 0.008 4.536
05 - 202244****** IQ7+M [5] VCOP 0.000 0.159 0.372 0.008 4.272
06 - 202245****** IQ7+M [5] VCOP 0.000 0.131 0.302 0.008 4.338
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.271 0.636 0.047 4.640 0.000 kW
0.753 kWh
0.000 kW
3.765 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.270 0.749 0.052 5.205
09 - 202217****** IQ7+ [5] VCOP 0.000 0.275 0.822 0.060 5.487
10 - 202244****** IQ7+M [5] VCOP 0.000 0.272 0.827 0.068 5.423
11 - 202224****** IQ7+M [5] VCOP 0.000 0.275 0.730 0.065 5.139
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.029 0.103 0.002 2.061 0.000 kW
0.075 kWh
0.000 kW
0.300 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.020 0.080 0.002 2.357
14 - 202216****** IQ7+ [5] VCOP 0.000 0.016 0.069 0.002 2.462
15 - 202245****** IQ7+M [5] VCOP 0.000 0.012 0.048 0.001 2.439
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 21.109
Panel Layout Each Group Production

Charger History
Voltage PV 2.49 V Voltage Charge 52.44 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.3 °C / 23.0 °C Flags 00/00/00 Energy Today 5.050 kWh @ 2025-12-15 23:55
voltage in/out power and energy

Battery History
Voltage 52.64 V Current/Power -1.44 A (-75 W)
Remain Capacity/Energy 204.0 Ah (10.4 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 34.4 % State Of Health 98.9 %
Run Time 5d 21h 40m to empty Report Date 2025-12-15 23:56
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.