Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.210 kW
05/19/2026 16:22 (2183 days) Production Consumption NET Usage
Now 2.955 kW 2.745 kW -0.210 kW
Today 25.550 kWh (1.559 kW) 19.444 kWh (1.186 kW) -6.106 kWh (-0.373 kW)
  - This Week 87.754 kWh (32.704 kWh/day) 68.271 kWh (25.443 kWh/day) -19.483 kWh (-7.261 kWh/day)
  - This Month 489.570 kWh (26.204 kWh/day) 267.993 kWh (14.344 kWh/day) -221.577 kWh (-11.860 kWh/day)
  - This Year 2.443 MWh (17.613 kWh/day) 2.328 MWh (16.784 kWh/day) -0.115 MWh (-0.828 kWh/day)
Yesterday 30.445 kWh (1.269 kW) 27.538 kWh (1.148 kW) -2.907 kWh (-0.121 kW)
Last 7 Days 197.401 kWh (28.200 kWh/day) 118.454 kWh (16.922 kWh/day) -78.947 kWh (-11.278 kWh/day)
Last 30 Days (04/19/2026) 721.432 kWh (24.048 kWh/day) 417.568 kWh (13.919 kWh/day) -303.864 kWh (-10.129 kWh/day)
Last One Year 6.370 MWh (17.453 kWh/day) 7.753 MWh (21.242 kWh/day) 1.383 MWh (3.789 kWh/day)
Lifetime Since PTO 38.008 MWh (17.406 kW/day) 41.838 MWh (19.160 kW/day) 3.830 MWh (1.754 kW/day)
Lifetime Since Install 38.042 MWh 42.418 MWh 4.376 MWh
Voltage/Current 246.5 V / 12.0 A 246.3 V / 11.1 A 246.4 V / -0.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/07/2024 23:59 (23.9 hours) Number of Devices 17 set
Current Power 0.229 kW (0.013 kW/panel) Today Energy 20.302 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.215 1.060 1.041 7.277 0.000 kW
1.029 kWh
0.000 kW
6.172 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.204 1.003 0.995 6.903
03 - 202224****** IQ7+M [5] VCOP 0.000 0.210 1.031 1.019 7.099
04 - 202232****** IQ7+ [5] VCOP 0.000 0.211 1.038 1.025 7.133
05 - 202244****** IQ7+M [5] VCOP 0.000 0.205 1.014 1.000 6.960
06 - 202245****** IQ7+M [5] VCOP 0.000 0.208 1.026 1.012 7.150
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.258 1.226 1.065 7.942 0.000 kW
1.324 kWh
0.000 kW
6.620 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.259 1.302 1.218 8.694
09 - 202217****** IQ7+ [5] VCOP 0.000 0.259 1.391 1.325 9.218
10 - 202244****** IQ7+M [5] VCOP 0.000 0.256 1.355 1.302 9.103
11 - 202224****** IQ7+M [5] VCOP 0.000 0.261 1.346 1.259 8.973
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.100 0.433 0.464 3.367 0.000 kW
0.502 kWh
0.000 kW
2.007 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.108 0.513 0.535 3.877
14 - 202216****** IQ7+ [5] VCOP 0.000 0.112 0.536 0.560 4.064
15 - 202245****** IQ7+M [5] VCOP 0.000 0.111 0.524 0.551 3.996
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.751 kWh
0.229 kW
5.502 kWh
17 - 122214****** IQ7PD [5] VCOP 0.229 0.230 5.502 5.508 23.265
Panel Layout Each Group Production

Charger History
Voltage PV 0.44 V Voltage Charge 52.20 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.3 °C / 26.4 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-11-07 23:57
voltage in/out power and energy

Battery History
Voltage 52.46 V Current/Power -6.34 A (-0.333 kW)
Remain Capacity/Energy 312.3 Ah (16.0 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 52.7 % State Of Health 98.9 %
Run Time 2d 1h 15m to empty Report Date 2024-11-07 23:57
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.42 V Cell (MIN/MAX) 3.270 V / 3.281 V (0.011 V)
Current/Power -1.64 A (-85 W) Runtime 2d 15h 28m to empty
Remain Capacity/Energy 104.1 Ah (5.3 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 52.7 % State Of Health 98.8 %
Temperature 22.0 °C Cycle 172
MOSFET CFET = ON, DFET = ON Reported 2024-11-07 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.270 V 3.272 V 3.271 V 3.273 V 3.274 V 3.274 V 3.276 V 3.274 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.276 V 3.277 V 3.277 V 3.279 V 3.279 V 3.280 V 3.281 V 3.281 V
pack voltage and current cell voltages
JpGraph Error: 25107 Can't write to file "images/chart_batt2_1.png". Check that the process running PHP has enough permission.