Date Offset  [+30][+10][+05][+01][-01][-05]

Exporting to grid by 1.675 kW
10/20/2025 13:19 (1972 days) Production Consumption NET Usage
Now 2.027 kW 0.352 kW -1.675 kW
Today 4.969 kWh (0.373 kW) 7.421 kWh (0.556 kW) 2.452 kWh (0.184 kW)
  - This Week 22.644 kWh (14.556 kWh/day) 25.883 kWh (16.638 kWh/day) 3.239 kWh (2.082 kWh/day)
  - This Month 333.734 kWh (17.066 kWh/day) 331.673 kWh (16.961 kWh/day) -2.061 kWh (-0.105 kWh/day)
  - This Year 5.433 MWh (18.571 kWh/day) 6.187 MWh (21.147 kWh/day) 0.754 MWh (2.576 kWh/day)
Yesterday 17.675 kWh (0.736 kW) 18.462 kWh (0.769 kW) 0.787 kWh (0.033 kW)
Last 7 Days 108.364 kWh (15.480 kWh/day) 101.909 kWh (14.558 kWh/day) -6.455 kWh (-0.922 kWh/day)
Last 30 Days 513.806 kWh (17.127 kWh/day) 564.177 kWh (18.806 kWh/day) 50.371 kWh (1.679 kWh/day)
Last One Year 6.274 MWh (17.189 kWh/day) 7.416 MWh (20.318 kWh/day) 1.142 MWh (3.129 kWh/day)
Lifetime Since PTO 34.884 MWh (17.685 kW/day) 38.139 MWh (19.335 kW/day) 3.255 MWh (1.650 kW/day)
Lifetime Since Install 34.918 MWh 38.719 MWh 3.801 MWh
Voltage/Current 253.5 V / 8.0 A 253.4 V / 1.4 A 253.5 V / -6.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/14/2025 23:45 (10.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.405 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.157 0.591 0.301 6.243 0.000 kW
0.576 kWh
0.000 kW
3.456 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.159 0.562 0.286 5.958
03 - 202224****** IQ7+M [5] VCOP 0.000 0.165 0.586 0.300 6.166
04 - 202232****** IQ7+ [5] VCOP 0.000 0.165 0.587 0.299 6.180
05 - 202244****** IQ7+M [5] VCOP 0.000 0.158 0.555 0.280 5.907
06 - 202245****** IQ7+M [5] VCOP 0.000 0.153 0.575 0.291 6.040
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.168 0.553 0.273 6.105 0.000 kW
0.555 kWh
0.000 kW
2.777 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.175 0.555 0.274 6.504
09 - 202217****** IQ7+ [5] VCOP 0.000 0.165 0.556 0.275 6.615
10 - 202244****** IQ7+M [5] VCOP 0.000 0.170 0.558 0.276 6.662
11 - 202224****** IQ7+M [5] VCOP 0.000 0.171 0.554 0.271 6.684
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.117 0.507 0.271 4.171 0.000 kW
0.543 kWh
0.000 kW
2.172 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.119 0.535 0.288 4.427
14 - 202216****** IQ7+ [5] VCOP 0.000 0.125 0.565 0.311 4.613
15 - 202245****** IQ7+M [5] VCOP 0.000 0.127 0.566 0.310 4.609
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 32.466 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 1.13 V Voltage Charge 52.39 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 29.1 °C / 26.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-10-14 23:56
voltage in/out power and energy

Battery History
Voltage 52.59 V Current/Power -1.80 A (-94 W)
Remain Capacity/Energy 193.8 Ah (9.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 32.7 % State Of Health 98.9 %
Run Time 4d 11h 39m to empty Report Date 2025-10-14 23:58
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.