Date Offset  [+30][+10][+05][+01][-01][-05]

Importing from grid by 0.146 kW
07/03/2026 06:43 (2228 days) Production Consumption NET Usage
Now 0.572 kW 0.718 kW 0.146 kW
Today 1.717 kWh (0.254 kW) 10.391 kWh (1.538 kW) 8.674 kWh (1.284 kW)
  - This Week 144.591 kWh (27.381 kWh/day) 170.529 kWh (32.293 kWh/day) 25.938 kWh (4.912 kWh/day)
  - This Month 62.990 kWh (27.611 kWh/day) 96.389 kWh (42.251 kWh/day) 33.399 kWh (14.640 kWh/day)
  - This Year 3.673 MWh (20.039 kWh/day) 3.383 MWh (18.459 kWh/day) -0.290 MWh (-1.580 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 173.388 kWh (24.770 kWh/day) 204.534 kWh (29.219 kWh/day) 31.146 kWh (4.449 kWh/day)
Last 30 Days (06/03/2026) 862.926 kWh (28.764 kWh/day) 794.709 kWh (26.490 kWh/day) -68.217 kWh (-2.274 kWh/day)
Last One Year 6.716 MWh (18.400 kWh/day) 7.750 MWh (21.233 kWh/day) 1.034 MWh (2.833 kWh/day)
Lifetime Since PTO 39.239 MWh (17.609 kW/day) 42.894 MWh (19.250 kW/day) 3.655 MWh (1.640 kW/day)
Lifetime Since Install 39.272 MWh 43.474 MWh 4.201 MWh
Voltage/Current 250.9 V / 2.3 A 250.9 V / 2.9 A 250.9 V / 0.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/27/2026 23:39 (20.5 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.676 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.169 0.708 1.327 11.118 0.000 kW
0.676 kWh
0.000 kW
4.057 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.161 0.669 1.268 10.398
03 - 202224****** IQ7+M [5] VCOP 0.000 0.174 0.696 1.316 10.583
04 - 202232****** IQ7+ [5] VCOP 0.000 0.168 0.685 1.311 10.660
05 - 202244****** IQ7+M [5] VCOP 0.000 0.123 0.618 1.257 9.533
06 - 202245****** IQ7+M [5] VCOP 0.000 0.155 0.683 1.296 10.771
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.125 0.600 1.260 9.797 0.000 kW
0.607 kWh
0.000 kW
3.034 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.128 0.604 1.282 9.758
09 - 202217****** IQ7+ [5] VCOP 0.000 0.129 0.608 1.284 9.871
10 - 202244****** IQ7+M [5] VCOP 0.000 0.127 0.610 1.286 10.009
11 - 202224****** IQ7+M [5] VCOP 0.000 0.128 0.612 1.295 10.161
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.207 0.722 1.138 10.917 0.000 kW
0.756 kWh
0.000 kW
3.025 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.202 0.749 1.171 10.946
14 - 202216****** IQ7+ [5] VCOP 0.000 0.213 0.775 1.200 11.296
15 - 202245****** IQ7+M [5] VCOP 0.000 0.211 0.779 1.203 11.338
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.322 3.966 7.589 37.829 0.000 kW
1.520 kWh
0.000 kW
4.560 kWh
17 - 122344****** IQ7AS [4] VCOP 0.000 0.204 0.594 1.172 1.195
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 7.984
Panel Layout Each Group Production

Charger History
Voltage PV 1.14 V Voltage Charge 52.47 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.1 °C / 26.0 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2026-06-27 23:58
voltage in/out power and energy

Battery History
Voltage 52.67 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 298.8 Ah (15.3 kWh) Full Capacity/Energy 548.1 Ah (28.1 kWh)
State Of Charge 54.5 % State Of Health 91.4 %
Run Time 8d 7h 12m to empty Report Date 2026-06-27 23:58
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.