Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.142 kW
03/21/2026 07:29 (2124 days) Production Consumption NET Usage
Now 0.139 kW 0.281 kW 0.142 kW
Today 0.027 kWh (0.004 kW) 3.149 kWh (0.420 kW) 3.122 kWh (0.416 kW)
  - This Week 113.764 kWh (18.022 kWh/day) 121.465 kWh (19.242 kWh/day) 7.701 kWh (1.220 kWh/day)
  - This Month 348.485 kWh (17.156 kWh/day) 325.492 kWh (16.024 kWh/day) -22.993 kWh (-1.132 kWh/day)
  - This Year 0.982 MWh (12.386 kWh/day) 1.425 MWh (17.971 kWh/day) 0.443 MWh (5.584 kWh/day)
Yesterday 19.934 kWh (0.831 kW) 13.045 kWh (0.544 kW) -6.889 kWh (-0.287 kW)
Last 7 Days 145.555 kWh (20.794 kWh/day) 133.585 kWh (19.084 kWh/day) -11.970 kWh (-1.710 kWh/day)
Last 30 Days (02/19/2026) 451.605 kWh (15.054 kWh/day) 499.838 kWh (16.661 kWh/day) 48.233 kWh (1.608 kWh/day)
Last One Year 6.083 MWh (16.665 kWh/day) 7.890 MWh (21.616 kWh/day) 1.807 MWh (4.951 kWh/day)
Lifetime Since PTO 36.548 MWh (17.205 kW/day) 40.936 MWh (19.270 kW/day) 4.388 MWh (2.066 kW/day)
Lifetime Since Install 36.582 MWh 41.516 MWh 4.934 MWh
Voltage/Current 249.2 V / 0.6 A 249.1 V / 1.1 A 249.2 V / 0.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/29/2024 23:53 (13.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 19.325 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.291 1.376 1.710 10.031 0.000 kW
1.335 kWh
0.000 kW
8.009 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.269 1.308 1.601 9.436
03 - 202224****** IQ7+M [5] VCOP 0.000 0.290 1.359 1.653 9.762
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.368 1.688 9.902
05 - 202244****** IQ7+M [5] VCOP 0.000 0.288 1.263 1.482 8.914
06 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.334 1.633 9.612
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.289 1.314 1.526 9.193 0.000 kW
1.307 kWh
0.000 kW
6.534 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.290 1.282 1.547 9.148
09 - 202217****** IQ7+ [5] VCOP 0.000 0.288 1.290 1.532 9.137
10 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.315 1.527 9.192
11 - 202224****** IQ7+M [5] VCOP 0.000 0.292 1.334 1.549 9.326
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.258 1.146 1.650 9.249 0.000 kW
1.195 kWh
0.000 kW
4.782 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.234 1.161 1.697 9.512
14 - 202216****** IQ7+ [5] VCOP 0.000 0.238 1.240 1.759 9.917
15 - 202245****** IQ7+M [5] VCOP 0.000 0.245 1.236 1.762 9.922
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.73 V Current/Power -1.80 A (-94 W)
Remain Capacity/Energy 324.0 Ah (16.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 54.6 % State Of Health 98.9 %
Run Time 7d 12h 0m to empty Report Date 2024-07-29 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.