Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.838 kW
03/21/2026 09:45 (2124 days) Production Consumption NET Usage
Now 1.318 kW 0.480 kW -0.838 kW
Today 1.586 kWh (0.162 kW) 5.024 kWh (0.514 kW) 3.438 kWh (0.352 kW)
  - This Week 115.323 kWh (18.000 kWh/day) 123.340 kWh (19.252 kWh/day) 8.017 kWh (1.251 kWh/day)
  - This Month 350.044 kWh (17.153 kWh/day) 327.367 kWh (16.042 kWh/day) -22.677 kWh (-1.111 kWh/day)
  - This Year 0.984 MWh (12.391 kWh/day) 1.427 MWh (17.973 kWh/day) 0.443 MWh (5.582 kWh/day)
Yesterday 19.934 kWh (0.831 kW) 13.045 kWh (0.544 kW) -6.889 kWh (-0.287 kW)
Last 7 Days 144.969 kWh (20.710 kWh/day) 132.736 kWh (18.962 kWh/day) -12.233 kWh (-1.748 kWh/day)
Last 30 Days (02/19/2026) 452.630 kWh (15.088 kWh/day) 500.896 kWh (16.697 kWh/day) 48.266 kWh (1.609 kWh/day)
Last One Year 6.083 MWh (16.664 kWh/day) 7.890 MWh (21.617 kWh/day) 1.808 MWh (4.953 kWh/day)
Lifetime Since PTO 36.550 MWh (17.205 kW/day) 40.938 MWh (19.270 kW/day) 4.388 MWh (2.066 kW/day)
Lifetime Since Install 36.584 MWh 41.518 MWh 4.934 MWh
Voltage/Current 250.0 V / 5.3 A 250.1 V / 1.9 A 250.0 V / -3.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/23/2024 23:14 (13.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.101 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.293 0.925 1.113 11.330 0.000 kW
0.899 kWh
0.000 kW
5.394 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.281 0.883 1.047 10.636
03 - 202224****** IQ7+M [5] VCOP 0.000 0.286 0.917 1.090 10.949
04 - 202232****** IQ7+ [5] VCOP 0.000 0.290 0.917 1.101 11.134
05 - 202244****** IQ7+M [5] VCOP 0.000 0.283 0.862 0.991 9.963
06 - 202245****** IQ7+M [5] VCOP 0.000 0.285 0.891 1.064 10.864
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.290 0.865 0.971 10.253 0.000 kW
0.865 kWh
0.000 kW
4.325 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.289 0.865 0.982 10.150
09 - 202217****** IQ7+ [5] VCOP 0.000 0.289 0.861 0.977 10.143
10 - 202244****** IQ7+M [5] VCOP 0.000 0.287 0.865 0.981 10.247
11 - 202224****** IQ7+M [5] VCOP 0.000 0.291 0.870 0.990 10.409
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.236 0.798 1.093 10.582 0.000 kW
0.846 kWh
0.000 kW
3.382 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.252 0.831 1.145 10.873
14 - 202216****** IQ7+ [5] VCOP 0.000 0.262 0.878 1.195 11.281
15 - 202245****** IQ7+M [5] VCOP 0.000 0.262 0.874 1.195 11.274
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.67 V Current/Power -1.59 A (-83 W)
Remain Capacity/Energy 234.6 Ah (12.0 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 39.6 % State Of Health 98.9 %
Run Time 6d 3h 32m to empty Report Date 2024-07-23 23:55
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.63 V Cell (MIN/MAX) 3.283 V / 3.295 V (0.012 V)
Current/Power -0.55 A (-28 W) Runtime 5d 22h 10m to empty
Remain Capacity/Energy 78.2 Ah (4.0 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 39.6 % State Of Health 98.8 %
Temperature 26.0 °C Cycle 160
MOSFET CFET = ON, DFET = ON Reported 2024-07-23 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.283 V 3.285 V 3.285 V 3.286 V 3.287 V 3.287 V 3.288 V 3.288 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.289 V 3.290 V 3.290 V 3.293 V 3.292 V 3.295 V 3.294 V 3.293 V
pack voltage and current cell voltages
Voltage 52.66 V Cell (MIN/MAX) 3.290 V / 3.292 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 58.2 Ah (3.0 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 58.5 % State Of Health 99.5 %
Temperature 26.4 °C Cycle 98
MOSFET CFET = ON, DFET = ON Reported 2024-07-23 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.291 V 3.290 V 3.292 V 3.290 V 3.291 V 3.292 V 3.290 V 3.292 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.290 V 3.290 V 3.290 V 3.290 V 3.292 V 3.290 V 3.290 V 3.290 V
pack voltage and current cell voltages
Voltage 52.70 V Cell (MIN/MAX) 3.293 V / 3.294 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 57.2 Ah (2.9 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 57.5 % State Of Health 99.5 %
Temperature 25.6 °C Cycle 101
MOSFET CFET = ON, DFET = ON Reported 2024-07-23 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.293 V 3.293 V 3.294 V 3.293 V 3.294 V 3.293 V 3.293 V 3.293 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.293 V 3.293 V 3.293 V 3.293 V 3.293 V 3.293 V 3.293 V 3.293 V
pack voltage and current cell voltages

Warning: unlink(images/chart_batt1_3.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
Voltage 52.67 V Cell (MIN/MAX) 3.292 V / 3.293 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 57.0 Ah (2.9 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 57.3 % State Of Health 99.5 %
Temperature 25.6 °C Cycle 103
MOSFET CFET = ON, DFET = ON Reported 2024-07-23 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.292 V 3.293 V 3.293 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V
pack voltage and current cell voltages
Voltage 52.67 V Cell (MIN/MAX) 3.290 V / 3.292 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 56.9 Ah (2.9 kWh) Full Capacity/Energy 99.2 Ah (5.1 kWh)
State Of Charge 57.4 % State Of Health 99.2 %
Temperature 26.3 °C Cycle 102
MOSFET CFET = ON, DFET = ON Reported 2024-07-23 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.290 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.291 V 3.292 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.292 V 3.292 V 3.291 V 3.291 V 3.292 V 3.292 V 3.292 V 3.292 V
pack voltage and current cell voltages