Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.328 kW
08/23/2025 17:31 (1914 days) Production Consumption NET Usage
Now 0.573 kW 2.901 kW 2.328 kW
Today 28.018 kWh (1.597 kW) 23.613 kWh (1.346 kW) -4.405 kWh (-0.251 kW)
  - This Week 150.753 kWh (22.400 kWh/day) 184.163 kWh (27.364 kWh/day) 33.410 kWh (4.964 kWh/day)
  - This Month 551.480 kWh (24.262 kWh/day) 675.088 kWh (29.700 kWh/day) 123.608 kWh (5.438 kWh/day)
  - This Year 4.309 MWh (18.358 kWh/day) 5.013 MWh (21.355 kWh/day) 0.703 MWh (2.997 kWh/day)
Yesterday 29.751 kWh (1.241 kW) 54.006 kWh (2.252 kW) 24.255 kWh (1.011 kW)
Last 7 Days 147.186 kWh (21.028 kWh/day) 200.430 kWh (28.634 kWh/day) 53.244 kWh (7.607 kWh/day)
Last 30 Days 701.595 kWh (23.387 kWh/day) 964.778 kWh (32.160 kWh/day) 263.183 kWh (8.773 kWh/day)
Last One Year 6.301 MWh (17.264 kWh/day) 6.954 MWh (19.051 kWh/day) 0.652 MWh (1.787 kWh/day)
Lifetime Since PTO 33.760 MWh (17.632 kW/day) 36.965 MWh (19.305 kW/day) 3.205 MWh (1.674 kW/day)
Lifetime Since Install 33.794 MWh 37.545 MWh 3.751 MWh
Voltage/Current 247.1 V / 2.3 A 246.9 V / 11.8 A 247.0 V / 9.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/20/2023 23:39 (8.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.981 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.197 0.983 0.819 4.687 0.000 kW
0.965 kWh
0.000 kW
5.793 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.188 0.938 0.781 4.472
03 - 202224****** IQ7+M [5] VCOP 0.000 0.194 0.982 0.822 4.684
04 - 202232****** IQ7+ [5] VCOP 0.000 0.194 0.990 0.832 4.735
05 - 202244****** IQ7+M [5] VCOP 0.000 0.190 0.947 0.794 4.514
06 - 202245****** IQ7+M [5] VCOP 0.000 0.191 0.952 0.795 4.548
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.254 1.023 0.941 5.123 0.000 kW
1.162 kWh
0.000 kW
5.810 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.256 1.176 0.968 5.639
09 - 202217****** IQ7+ [5] VCOP 0.000 0.254 1.247 1.037 6.043
10 - 202244****** IQ7+M [5] VCOP 0.000 0.250 1.222 1.022 5.892
11 - 202224****** IQ7+M [5] VCOP 0.000 0.254 1.142 0.967 5.558
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.064 0.277 0.290 1.581 0.000 kW
0.344 kWh
0.000 kW
1.378 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.076 0.358 0.352 1.928
14 - 202216****** IQ7+ [5] VCOP 0.000 0.080 0.375 0.373 2.046
15 - 202245****** IQ7+M [5] VCOP 0.000 0.082 0.368 0.367 2.014
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 4.812 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.