Importing from grid by 2.341 kW
08/23/2025 17:28 (1914 days) Production Consumption NET Usage
Now 0.569 kW 2.910 kW 2.341 kW
Today 27.975 kWh (1.599 kW) 23.480 kWh (1.342 kW) -4.495 kWh (-0.257 kW)
  - This Week 150.710 kWh (22.400 kWh/day) 184.030 kWh (27.352 kWh/day) 33.320 kWh (4.952 kWh/day)
  - This Month 551.437 kWh (24.262 kWh/day) 674.955 kWh (29.696 kWh/day) 123.518 kWh (5.435 kWh/day)
  - This Year 4.309 MWh (18.358 kWh/day) 5.013 MWh (21.355 kWh/day) 0.703 MWh (2.997 kWh/day)
Yesterday 29.751 kWh (1.241 kW) 54.006 kWh (2.252 kW) 24.255 kWh (1.011 kW)
Last 7 Days 147.186 kWh (21.028 kWh/day) 200.430 kWh (28.634 kWh/day) 53.244 kWh (7.607 kWh/day)
Last 30 Days 701.595 kWh (23.387 kWh/day) 964.778 kWh (32.160 kWh/day) 263.183 kWh (8.773 kWh/day)
Last One Year 6.301 MWh (17.264 kWh/day) 6.954 MWh (19.051 kWh/day) 0.652 MWh (1.787 kWh/day)
Lifetime Since PTO 33.760 MWh (17.632 kW/day) 36.965 MWh (19.305 kW/day) 3.204 MWh (1.674 kW/day)
Lifetime Since Install 33.794 MWh 37.544 MWh 3.751 MWh
Voltage/Current 246.9 V / 2.3 A 246.8 V / 11.8 A 246.8 V / 9.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/25/2023 23:50 (9.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.836 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.208 0.850 1.021 5.827 0.000 kW
0.838 kWh
0.000 kW
5.029 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.197 0.809 0.975 5.552
03 - 202224****** IQ7+M [5] VCOP 0.000 0.205 0.850 1.015 5.781
04 - 202232****** IQ7+ [5] VCOP 0.000 0.206 0.863 1.022 5.803
05 - 202244****** IQ7+M [5] VCOP 0.000 0.199 0.823 0.995 5.597
06 - 202245****** IQ7+M [5] VCOP 0.000 0.200 0.834 1.004 5.690
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.275 0.905 1.121 6.281 0.000 kW
0.999 kWh
0.000 kW
4.993 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.275 0.996 1.259 6.932
09 - 202217****** IQ7+ [5] VCOP 0.000 0.271 1.049 1.290 7.234
10 - 202244****** IQ7+M [5] VCOP 0.000 0.268 1.040 1.276 7.135
11 - 202224****** IQ7+M [5] VCOP 0.000 0.274 1.003 1.263 6.989
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.098 0.415 0.369 2.397 0.000 kW
0.454 kWh
0.000 kW
1.814 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.102 0.452 0.451 2.883
14 - 202216****** IQ7+ [5] VCOP 0.000 0.105 0.478 0.471 3.022
15 - 202245****** IQ7+M [5] VCOP 0.000 0.107 0.469 0.466 2.983
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 4.711 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.33 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 430.8 Ah (22.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 72.6 % State Of Health 98.9 %
Run Time 19d 22h 40m to empty Report Date 2023-11-25 23:59
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185