Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 1.433 kW
06/07/2025 17:14 (1837 days) Production Consumption NET Usage
Now 0.966 kW 2.399 kW 1.433 kW
Today 12.021 kWh (0.697 kW) 15.407 kWh (0.894 kW) 3.386 kWh (0.196 kW)
  - This Week 177.282 kWh (26.385 kWh/day) 130.952 kWh (19.490 kWh/day) -46.330 kWh (-6.895 kWh/day)
  - This Month 177.282 kWh (26.385 kWh/day) 130.952 kWh (19.490 kWh/day) -46.330 kWh (-6.895 kWh/day)
  - This Year 2.578 MWh (16.348 kWh/day) 2.485 MWh (15.755 kWh/day) -0.094 MWh (-0.593 kWh/day)
Yesterday 25.293 kWh (1.053 kW) 27.492 kWh (1.144 kW) 2.199 kWh (0.092 kW)
Last 7 Days 181.940 kWh (25.989 kWh/day) 148.542 kWh (21.219 kWh/day) -33.398 kWh (-4.771 kWh/day)
Last 30 Days 618.729 kWh (20.624 kWh/day) 570.095 kWh (19.003 kWh/day) -48.634 kWh (-1.621 kWh/day)
Last One Year 6.547 MWh (17.937 kWh/day) 6.282 MWh (17.211 kWh/day) -0.265 MWh (-0.726 kWh/day)
Lifetime Since PTO 32.029 MWh (17.429 kW/day) 34.437 MWh (18.739 kW/day) 2.408 MWh (1.310 kW/day)
Lifetime Since Install 32.063 MWh 35.017 MWh 2.954 MWh
Voltage/Current 248.6 V / 3.9 A 248.6 V / 9.7 A 248.6 V / 5.8 A
Meter Accumulated Grid Votlage Power

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_panel_inc.php on line 411

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/12/2023 23:11 (13.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.462 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.283 1.472 2.072 10.446 0.000 kW
1.425 kWh
0.000 kW
8.548 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.272 1.394 1.943 9.797
03 - 202224****** IQ7+M [5] VCOP 0.000 0.279 1.453 2.008 10.154
04 - 202232****** IQ7+ [5] VCOP 0.000 0.285 1.475 2.046 10.329
05 - 202244****** IQ7+M [5] VCOP 0.000 0.270 1.347 1.831 9.317
06 - 202245****** IQ7+M [5] VCOP 0.000 0.277 1.408 1.977 10.000
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.280 1.408 1.947 9.689 0.000 kW
1.423 kWh
0.000 kW
7.113 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.283 1.413 1.907 9.589
09 - 202217****** IQ7+ [5] VCOP 0.000 0.282 1.421 1.913 9.623
10 - 202244****** IQ7+M [5] VCOP 0.000 0.279 1.428 1.954 9.735
11 - 202224****** IQ7+M [5] VCOP 0.000 0.283 1.443 1.998 9.899
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.245 1.368 1.863 9.576 0.000 kW
1.416 kWh
0.000 kW
5.663 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.251 1.389 1.851 9.683
14 - 202216****** IQ7+ [5] VC-- 0.000 0.255 1.448 1.927 10.034
15 - 202245****** IQ7+M [5] VCOP 0.000 0.256 1.458 1.926 10.053
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.230 1.138 1.136 7.946 0.000 kW
1.138 kWh
0.000 kW
1.138 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 525.1 Ah (26.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 88.5 % State Of Health 98.9 %
Run Time 18d 5h 37m to empty Report Date 2023-08-12 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.23 V Cell (MIN/MAX) 3.322 V / 3.331 V (0.009 V)
Current/Power -0.43 A (-22 W) Runtime 16d 23h 5m to empty
Remain Capacity/Energy 175.1 Ah (9.0 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 88.5 % State Of Health 98.8 %
Temperature 25.0 °C Cycle 114
MOSFET CFET = ON, DFET = ON Reported 2023-08-12 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.322 V 3.323 V 3.323 V 3.324 V 3.325 V 3.325 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.327 V 3.328 V 3.328 V 3.329 V 3.330 V 3.330 V 3.331 V 3.330 V
pack voltage and current cell voltages
pack temperature