Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.543 kW
07/04/2026 08:53 (2229 days) Production Consumption NET Usage
Now 0.937 kW 0.394 kW -0.543 kW
Today 3.562 kWh (0.399 kW) 7.867 kWh (0.882 kW) 4.305 kWh (0.483 kW)
  - This Week 179.514 kWh (28.178 kWh/day) 209.784 kWh (32.929 kWh/day) 30.270 kWh (4.751 kWh/day)
  - This Month 97.913 kWh (29.042 kWh/day) 135.644 kWh (40.234 kWh/day) 37.731 kWh (11.191 kWh/day)
  - This Year 3.708 MWh (20.110 kWh/day) 3.422 MWh (18.563 kWh/day) -0.285 MWh (-1.548 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 187.901 kWh (26.843 kWh/day) 225.683 kWh (32.240 kWh/day) 37.782 kWh (5.397 kWh/day)
Last 30 Days (06/04/2026) 855.095 kWh (28.503 kWh/day) 815.051 kWh (27.168 kWh/day) -40.044 kWh (-1.335 kWh/day)
Last One Year 6.725 MWh (18.425 kWh/day) 7.762 MWh (21.265 kWh/day) 1.036 MWh (2.840 kWh/day)
Lifetime Since PTO 39.273 MWh (17.616 kW/day) 42.933 MWh (19.258 kW/day) 3.660 MWh (1.642 kW/day)
Lifetime Since Install 39.307 MWh 43.513 MWh 4.206 MWh
Voltage/Current 247.9 V / 3.8 A 247.9 V / 1.6 A 247.9 V / -2.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/06/2024 23:59 (23.9 hours) Number of Devices 18 set
Current Power 0.229 kW (0.013 kW/panel) Today Energy 19.033 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.278 0.960 1.924 9.861 0.000 kW
0.933 kWh
0.000 kW
5.597 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.278 0.911 1.840 9.383
03 - 202224****** IQ7+M [5] VCOP 0.000 0.283 0.949 1.923 9.766
04 - 202232****** IQ7+ [5] VCOP 0.000 0.288 0.951 1.955 9.866
05 - 202244****** IQ7+M [5] VCOP 0.000 0.272 0.898 1.772 9.153
06 - 202245****** IQ7+M [5] VCOP 0.000 0.271 0.929 1.817 9.406
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 0.956 1.930 9.828 0.000 kW
0.956 kWh
0.000 kW
4.778 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.287 0.958 1.994 9.937
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 0.938 1.939 9.739
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 0.958 1.994 10.013
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 0.968 2.041 10.202
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.172 0.743 1.534 7.725 0.000 kW
0.789 kWh
0.000 kW
3.157 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.171 0.773 1.559 7.893
14 - 202216****** IQ7+ [5] VCOP 0.000 0.180 0.821 1.644 8.328
15 - 202245****** IQ7+M [5] VCOP 0.000 0.188 0.820 1.638 8.292
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.076 kW
1.833 kWh
0.229 kW
5.500 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.229 0.231 5.500 5.482 33.334
Panel Layout Each Group Production

Charger History
Voltage PV 0.55 V Voltage Charge 52.22 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 31.6 °C / 28.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-09-06 23:57
voltage in/out power and energy

Battery History
Voltage 52.50 V Current/Power -6.37 A (-0.334 kW)
Remain Capacity/Energy 265.4 Ah (13.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 44.7 % State Of Health 98.9 %
Run Time 1d 17h 39m to empty Report Date 2024-09-06 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.