Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.907 kW
07/03/2026 09:42 (2228 days) Production Consumption NET Usage
Now 2.334 kW 0.427 kW -1.907 kW
Today 5.346 kWh (0.549 kW) 15.946 kWh (1.639 kW) 10.600 kWh (1.089 kW)
  - This Week 148.220 kWh (27.425 kWh/day) 176.084 kWh (32.580 kWh/day) 27.864 kWh (5.156 kWh/day)
  - This Month 66.619 kWh (27.698 kWh/day) 101.944 kWh (42.384 kWh/day) 35.325 kWh (14.687 kWh/day)
  - This Year 3.676 MWh (20.046 kWh/day) 3.389 MWh (18.477 kWh/day) -0.288 MWh (-1.569 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 175.767 kWh (25.110 kWh/day) 209.454 kWh (29.922 kWh/day) 33.687 kWh (4.812 kWh/day)
Last 30 Days (06/03/2026) 862.230 kWh (28.741 kWh/day) 797.409 kWh (26.580 kWh/day) -64.821 kWh (-2.161 kWh/day)
Last One Year 6.717 MWh (18.402 kWh/day) 7.752 MWh (21.239 kWh/day) 1.036 MWh (2.838 kWh/day)
Lifetime Since PTO 39.242 MWh (17.610 kW/day) 42.899 MWh (19.251 kW/day) 3.657 MWh (1.641 kW/day)
Lifetime Since Install 39.276 MWh 43.479 MWh 4.203 MWh
Voltage/Current 248.3 V / 9.4 A 248.3 V / 1.7 A 248.3 V / -7.7 A
Meter

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 04/27/2026 23:57 (18.0 hours) Number of Devices 18 set
Current Power 0.321 kW (0.018 kW/panel) Today Energy 38.790 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.294 2.276 1.693 10.457 0.000 kW
2.192 kWh
0.000 kW
13.151 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.281 2.141 1.625 9.932
03 - 202224****** IQ7+M [5] VCOP 0.000 0.291 2.242 1.688 10.348
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 2.290 1.681 10.403
05 - 202244****** IQ7+M [5] VCOP 0.000 0.282 2.031 1.619 9.580
06 - 202245****** IQ7+M [5] VCOP 0.000 0.288 2.171 1.658 10.071
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.292 2.174 1.733 9.977 0.000 kW
2.191 kWh
0.000 kW
10.954 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 2.159 1.666 10.020
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 2.150 1.669 10.003
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 2.206 1.730 10.160
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.266 1.773 10.328
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.247 2.033 1.286 9.229 0.000 kW
2.064 kWh
0.000 kW
8.254 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.252 2.002 1.262 9.274
14 - 202216****** IQ7+ [5] VCOP 0.000 0.255 2.105 1.357 9.633
15 - 202245****** IQ7+M [5] VCOP 0.000 0.257 2.114 1.359 9.661
wind 16 - 202320****** IQ7XS [0] ---- 0.321 0.322 5.395 0.000 38.887 0.107 kW
2.143 kWh
0.321 kW
6.430 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.150 1.035 0.627 4.552
Panel Layout Each Group Production

Charger History
Voltage PV 1.19 V Voltage Charge 52.82 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.0 °C / 25.5 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2026-04-27 23:58
voltage in/out power and energy

Battery History
Voltage 53.09 V Current/Power -7.86 A (-0.417 kW)
Remain Capacity/Energy 405.6 Ah (20.8 kWh) Full Capacity/Energy 548.1 Ah (28.1 kWh)
State Of Charge 74.0 % State Of Health 91.4 %
Run Time 2d 3h 36m to empty Report Date 2026-04-27 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.