Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.207 kW
07/04/2026 07:44 (2229 days) Production Consumption NET Usage
Now 0.798 kW 0.591 kW -0.207 kW
Today 2.472 kWh (0.318 kW) 6.718 kWh (0.864 kW) 4.246 kWh (0.546 kW)
  - This Week 178.424 kWh (28.219 kWh/day) 208.635 kWh (32.997 kWh/day) 30.211 kWh (4.778 kWh/day)
  - This Month 96.823 kWh (29.133 kWh/day) 134.495 kWh (40.468 kWh/day) 37.672 kWh (11.335 kWh/day)
  - This Year 3.707 MWh (20.110 kWh/day) 3.421 MWh (18.561 kWh/day) -0.285 MWh (-1.548 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 187.945 kWh (26.849 kWh/day) 224.856 kWh (32.122 kWh/day) 36.911 kWh (5.273 kWh/day)
Last 30 Days (06/04/2026) 855.537 kWh (28.518 kWh/day) 811.735 kWh (27.058 kWh/day) -43.802 kWh (-1.460 kWh/day)
Last One Year 6.725 MWh (18.425 kWh/day) 7.761 MWh (21.263 kWh/day) 1.036 MWh (2.838 kWh/day)
Lifetime Since PTO 39.272 MWh (17.616 kW/day) 42.932 MWh (19.258 kW/day) 3.660 MWh (1.642 kW/day)
Lifetime Since Install 39.306 MWh 43.512 MWh 4.206 MWh
Voltage/Current 248.1 V / 3.2 A 248.0 V / 2.4 A 248.1 V / -0.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/06/2024 23:32 (19.4 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 24.360 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.290 1.419 1.727 10.077 0.000 kW
1.344 kWh
0.000 kW
8.065 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.276 1.317 1.604 9.456
03 - 202224****** IQ7+M [5] VCOP 0.000 0.285 1.368 1.668 9.815
04 - 202232****** IQ7+ [5] VCOP 0.000 0.291 1.396 1.718 9.992
05 - 202244****** IQ7+M [5] VCOP 0.000 0.275 1.224 1.488 8.921
06 - 202245****** IQ7+M [5] VCOP 0.000 0.281 1.342 1.631 9.643
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.286 1.251 1.564 9.317 0.000 kW
1.267 kWh
0.000 kW
6.333 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.288 1.274 1.594 9.210
09 - 202217****** IQ7+ [5] VCOP 0.000 0.284 1.264 1.578 9.214
10 - 202244****** IQ7+M [5] VCOP 0.000 0.282 1.263 1.568 9.341
11 - 202224****** IQ7+M [5] VCOP 0.000 0.289 1.281 1.598 9.490
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.245 1.325 1.648 9.112 0.000 kW
1.373 kWh
0.000 kW
5.494 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.253 1.370 1.682 9.301
14 - 202216****** IQ7+ [5] VCOP 0.000 0.253 1.399 1.755 9.754
15 - 202245****** IQ7+M [5] VCOP 0.000 0.256 1.400 1.754 9.744
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
1.489 kWh
0.000 kW
4.468 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.230 4.468 5.496 27.349
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.