Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.884 kW
07/04/2026 11:05 (2229 days) Production Consumption NET Usage
Now 3.448 kW 0.564 kW -2.884 kW
Today 9.130 kWh (0.821 kW) 10.893 kWh (0.979 kW) 1.763 kWh (0.159 kW)
  - This Week 185.082 kWh (28.639 kWh/day) 212.810 kWh (32.930 kWh/day) 27.728 kWh (4.291 kWh/day)
  - This Month 103.481 kWh (29.881 kWh/day) 138.670 kWh (40.042 kWh/day) 35.189 kWh (10.161 kWh/day)
  - This Year 3.713 MWh (20.130 kWh/day) 3.425 MWh (18.570 kWh/day) -0.288 MWh (-1.561 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 190.716 kWh (27.245 kWh/day) 226.977 kWh (32.425 kWh/day) 36.261 kWh (5.180 kWh/day)
Last 30 Days (06/04/2026) 854.280 kWh (28.476 kWh/day) 819.190 kWh (27.306 kWh/day) -35.090 kWh (-1.170 kWh/day)
Last One Year 6.725 MWh (18.426 kWh/day) 7.764 MWh (21.271 kWh/day) 1.038 MWh (2.845 kWh/day)
Lifetime Since PTO 39.279 MWh (17.618 kW/day) 42.936 MWh (19.259 kW/day) 3.657 MWh (1.640 kW/day)
Lifetime Since Install 39.313 MWh 43.516 MWh 4.203 MWh
Voltage/Current 248.8 V / 13.9 A 248.7 V / 2.3 A 248.7 V / -11.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/29/2024 23:28 (14.4 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 17.594 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.225 2.350 13.417 0.000 kW
1.199 kWh
0.000 kW
7.194 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.175 2.179 12.550
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.217 2.208 12.728
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.225 2.265 12.953
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.165 1.954 11.312
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.188 2.250 12.896
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.149 2.133 11.970 0.000 kW
1.156 kWh
0.000 kW
5.780 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.153 2.041 11.692
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.154 2.066 11.804
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.155 2.105 11.920
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.169 2.144 12.132
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.292 1.097 2.261 12.797 0.000 kW
1.155 kWh
0.000 kW
4.619 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.296 1.142 2.258 12.991
14 - 202216****** IQ7+ [5] VCOP 0.000 0.296 1.190 2.392 13.578
15 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.190 2.391 13.552
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.60 V Current/Power -2.01 A (-0.106 kW)
Remain Capacity/Energy 251.1 Ah (12.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 42.3 % State Of Health 98.9 %
Run Time 5d 4h 55m to empty Report Date 2024-06-29 23:57
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.