Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
---|
Importing from grid by 6.671 kW | |||
---|---|---|---|
08/23/2025 00:43 (1914 days) | Production | Consumption | NET Usage |
Now | 0.000 kW | 6.671 kW | 6.671 kW |
Today | 0.000 kWh (0.000 kW) | 4.977 kWh (6.668 kW) | 4.977 kWh (6.668 kW) |
- This Week | 122.735 kWh (20.353 kWh/day) | 165.527 kWh (27.449 kWh/day) | 42.792 kWh (7.096 kWh/day) |
- This Month | 523.462 kWh (23.761 kWh/day) | 656.452 kWh (29.797 kWh/day) | 132.990 kWh (6.037 kWh/day) |
- This Year | 4.281 MWh (18.293 kWh/day) | 4.994 MWh (21.339 kWh/day) | 0.713 MWh (3.046 kWh/day) |
Yesterday | 29.751 kWh (1.241 kW) | 54.006 kWh (2.252 kW) | 24.255 kWh (1.011 kW) |
Last 7 Days | 147.186 kWh (21.028 kWh/day) | 200.430 kWh (28.634 kWh/day) | 53.244 kWh (7.607 kWh/day) |
Last 30 Days | 701.595 kWh (23.387 kWh/day) | 964.778 kWh (32.160 kWh/day) | 263.183 kWh (8.773 kWh/day) |
Last One Year | 6.301 MWh (17.264 kWh/day) | 6.954 MWh (19.051 kWh/day) | 0.652 MWh (1.787 kWh/day) |
Lifetime Since PTO | 33.732 MWh (17.624 kW/day) | 36.946 MWh (19.303 kW/day) | 3.214 MWh (1.679 kW/day) |
Lifetime Since Install | 33.766 MWh | 37.526 MWh | 3.760 MWh |
Voltage/Current | 251.6 V / 0.0 A | 251.6 V / 26.5 A | 251.6 V / 26.5 A |
![]() |
Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Recent Report Data/Time | 08/15/2023 23:06 (13.2 hours) | Number of Devices | 16 set | |||||||
Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 14.256 kWh | |||||||
Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.272 | 0.938 | 1.429 | 10.736 | 0.000 kW 0.914 kWh |
0.000 kW 5.487 kWh |
02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.259 | 0.891 | 1.361 | 10.113 | |||
03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.269 | 0.930 | 1.408 | 10.477 | |||
04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.272 | 0.932 | 1.415 | 10.616 | |||
05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.256 | 0.886 | 1.336 | 9.706 | |||
06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.266 | 0.910 | 1.390 | 10.302 | |||
front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.284 | 0.925 | 1.394 | 10.186 | 0.000 kW 0.908 kWh |
0.000 kW 4.542 kWh |
08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.284 | 0.883 | 1.397 | 10.065 | |||
09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.287 | 0.887 | 1.400 | 10.108 | |||
10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.283 | 0.911 | 1.395 | 10.245 | |||
11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.284 | 0.938 | 1.409 | 10.400 | |||
back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.188 | 0.738 | 1.162 | 9.458 | 0.000 kW 0.771 kWh |
0.000 kW 3.086 kWh |
13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.194 | 0.751 | 1.191 | 9.494 | |||
14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.197 | 0.797 | 1.235 | 9.910 | |||
15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.197 | 0.800 | 1.238 | 9.921 | |||
wind | 16 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.230 | 1.141 | 1.121 | 7.921 | 0.000 kW 1.141 kWh |
0.000 kW 1.141 kWh |
![]() ![]() |
Battery History | |||
---|---|---|---|
Voltage | 52.72 V | Current/Power | -1.50 A (-79 W) |
Remain Capacity/Energy | 244.8 Ah (12.5 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
State Of Charge | 41.3 % | State Of Health | 98.9 % |
Run Time | 6d 19h 12m to empty | Report Date | 2023-08-15 23:57 |
![]() ![]() |
Voltage | 52.72 V | Cell (MIN/MAX) | 3.288 V / 3.301 V (0.013 V) |
---|---|---|---|
Current/Power | -0.48 A (-25 W) | Runtime | 7d 2h 0m to empty |
Remain Capacity/Energy | 81.6 Ah (4.2 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
State Of Charge | 41.3 % | State Of Health | 98.8 % |
Temperature | 25.0 °C | Cycle | 115 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-08-15 23:57 |
Voltage | 52.70 V | Cell (MIN/MAX) | 3.293 V / 3.295 V (0.002 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 60.6 Ah (3.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
State Of Charge | 60.9 % | State Of Health | 99.5 % |
Temperature | 25.0 °C | Cycle | 60 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-08-15 23:59 |
Voltage | 52.74 V | Cell (MIN/MAX) | 3.295 V / 3.296 V (0.001 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 59.9 Ah (3.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
State Of Charge | 60.2 % | State Of Health | 99.5 % |
Temperature | 25.9 °C | Cycle | 63 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-08-15 23:58 |
Voltage | 52.72 V | Cell (MIN/MAX) | 3.293 V / 3.295 V (0.002 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 60.4 Ah (3.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
State Of Charge | 60.7 % | State Of Health | 99.5 % |
Temperature | 26.4 °C | Cycle | 65 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-08-15 23:59 |
Voltage | 52.70 V | Cell (MIN/MAX) | 3.293 V / 3.295 V (0.002 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 59.0 Ah (3.0 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
State Of Charge | 59.5 % | State Of Health | 99.2 % |
Temperature | 25.0 °C | Cycle | 63 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-08-15 23:59 |